Modern intraocular lens implants in children with new age limitations.

J Cataract Refract Surg

Department of Ophthalmology, University of Pittsburgh, School of Medicine, Pennsylvania.

Published: September 1987

Seventy-three children received modern designs of posterior and flexible anterior chamber intraocular lenses. Twenty-eight (38%) had anterior chamber and 45 (62%) had posterior chamber lenses implanted. Postoperative implant complications occurred in 38 (54%) eyes; the most frequent was secondary membrane formation. Six eyes (22%) with anterior chamber lenses and 25 eyes (58%) with posterior chamber lenses required posterior capsulotomies. Seventy percent of the posterior chamber lens recipients less than six years of age developed secondary membranes. All of these eyes had a discission except one Nd:YAG laser patient. Forty-eight percent of the patients with posterior chamber lenses over six years of age required posterior capsulotomies: 55% had Nd:YAG laser capsulotomies and 45% had discissions. Based upon these observations, we now recommend primary implantation of flexible anterior chamber lenses in three- to six-year old children who have tissue-free visual axes and for all secondary implantations. Primary posterior chamber lenses are recommended for children six years of age and older and for younger children who will tolerate a Nd:YAG laser capsulotomy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(87)80102-5DOI Listing

Publication Analysis

Top Keywords

chamber lenses
24
posterior chamber
20
anterior chamber
16
years age
12
ndyag laser
12
chamber
9
posterior
8
flexible anterior
8
required posterior
8
posterior capsulotomies
8

Similar Publications

Purpose: To evaluate the impact of Implantable Collamer Lens (ICL) implantation on anterior chamber angle parameters and posterior segment structures in highly myopic eyes and explore potential correlations between these changes. The study aimed to assess alterations in superficial and deep vessel density (SVD, DVD), foveal avascular zone (FAZ) area, and retinal nerve fiber layer (RNFL) thickness to clarify the safety profile of ICL implantation.

Methods: Prospective observational study, included 36 highly myopic eyes undergoing ICL implantation in surgery group and 23 non-surgical control eyes in non-surgery group.

View Article and Find Full Text PDF

Purpose: To describe a custom bent 27-gauge needle-guided suture snare technique for scleral fixation of posterior chamber intraocular lenses (PCIOL).

Methods: An 8-0 polypropylene suture was threaded into the lumen of a custom bent 27-gauge needle, and the needle tip was advanced into the eye from the intraocular lens (IOL) fixation point. The suture was threaded through the posterior limbal incision inside the IOL haptic loop and pulled out.

View Article and Find Full Text PDF

Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth.

BMC Ophthalmol

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, China.

Purpose: To evaluate the predictive accuracy of 11 intraocular lens (IOL) calculation formulas in eyes with an axial length (AL) less than 22.00 mm.

Methods: New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.

View Article and Find Full Text PDF

A portable optical detection system for rapid quantification of two rheumatoid arthritis biomarkers.

Anal Chim Acta

January 2025

Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan; Institute of NanoEngineering and Microsystems, National Tsing Hua University, Hsinchu, Taiwan. Electronic address:

Background: Rheumatoid arthritis (RA) is a chronic autoimmune disease that causes joint damage and progressive destruction of adjacent cartilage and bones. Quick and accurate detection of rheumatoid factors (RF) and anti-cyclic citrullinated peptide antibodies (anti-CCP) in serum is effective in diagnosing RA and preventing its progression. However, current methods for detecting these two biomarkers are costly, time-consuming, labor-intensive, and require specialized equipment.

View Article and Find Full Text PDF

Background: To evaluate the biosafety, reduction in anterior capsule opacification, and fluctuation in intraocular pressure (IOP) of a new phakic refractive lens (PRL) with a sinusoidal drainage groove design.

Methods: This self-controlled experiment was performed on eight eyes of four rabbits. Each rabbit was implanted with a sinusoidal PRL (PRL-S5) in the right eye and a conventional posterior chamber PRL (PC-PRL) in the left eye.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!