Differential effect of guanethidine on dopamine and norepinephrine pools in urine, heart and superior cervical ganglion in the rat.

J Neural Transm

Laboratoire de Physiologie, UA CNRS 1196, Faculté de Médecine, Lyon, France.

Published: November 1987

The time-related changes of dopamine (DA) and norepinephrine (NE) pools were investigated in heart, superior cervical ganglion (SCG) and urine in rats treated chronically with guanethidine (50 mg/kg i.p. five days each week). The efficiency of sympathectomy was assessed by the great loss of NE in heart and superior cervical ganglion (SCG) (-96% and -76% respectively of control values on day 18) together with the ready reduction of NE and 3-methoxy-4-hydroxyphenylglycol (MHPG) in urine. The pattern of changes was quite different for DA, which was less readily affected and at a lesser extent than NE in heart and SCG thus suggesting the presence of norepinephrine-independent DA stores. Similarly the urinary excretion of free DA, free 3,4-dihydroxyphenylacetic acid (DOPAC) and free homovanillic acid (HVA) was slightly decreased only from the 9th day, whereas urinary conjugated DA remained unaltered. These results indicate that the greatest portion of urine free and conjugated DA, free DOPAC and free HVA derives from peripheral pools located outside noradrenergic neurons. Alternatively, the time-course of DA sensitivity to guanethidine suggests that a portion of urine DA may originate from DA stored independently from NE in noradrenergic neurons.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF01252506DOI Listing

Publication Analysis

Top Keywords

heart superior
12
superior cervical
12
cervical ganglion
12
dopamine norepinephrine
8
norepinephrine pools
8
ganglion scg
8
dopac free
8
portion urine
8
noradrenergic neurons
8
free
6

Similar Publications

Cardiac Positron Emission Tomography (PET) can be used for the assessment of myocardial perfusion. Compared to other cardiac imaging techniques, notably Single Photon Emission Computer Tomography (SPECT), cardiac PET offers superior image resolution, higher accuracy, quantitative measures of myocardial perfusion, lower radiation exposure, and shorter image acquisition time. However, PET tends to be costlier and less widely available than SPECT due to the specialized equipment needed for generating the necessary radiotracers.

View Article and Find Full Text PDF

Objectives: While ketone bodies are not the main heart fuel, exercise may increase their uptake. Objectives: This study aimed to investigate the effect of 6-week endurance training and Pyruvate dehydrogenase kinase 4 )PDK4( inhibition on ketone bodies metabolism in the heart of diabetic rats with emphasis on the role of Peroxisome proliferator-activated receptor-gamma coactivator PGC-1alpha (PGC-1α).

Materials And Methods: Sixty male Wistar rats were divided into eight groups: healthy control group (CONT), endurance training group (TRA), diabetic group (DM), DM + EX group, Dichloroacetate (DCA) group, DM + DCA group, TRA + DCA group, and DM + TRA + DCA group.

View Article and Find Full Text PDF

Predictive value of CT-based and AI-reconstructed 3D-TAPSE in patients undergoing transcatheter tricuspid valve repair.

Front Cardiovasc Med

January 2025

Clinic for General and Interventional Cardiology/Angiology, Herz- und Diabeteszentrum, NRW, Ruhr-Universität Bochum, Medizinische Fakultät OWL (Universität Bielefeld), Bad Oeynhausen, Germany.

Background: The tricuspid annular plane systolic excursion (TAPSE) assessed by echocardiography has failed in predicting outcomes in patients with severe tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI). Considering the complex shape of the tricuspid annulus and right ventricle, as well as the difficult echocardiographic image acquisition of the right heart, cardiac computed tomography (CT) might be superior for the analysis of the annular excursion. Thus, this study aimed to analyze whether CT-captured TAPSE provides additional value in predicting outcomes after TTVI.

View Article and Find Full Text PDF

Effect of different root canal irrigation regimes microbubble emulsion (MBE) via riboflavin photosensitizer (RFP), cerium oxide (CeO) nanoparticles (NPs), and Nd: YAP laser on antibacterial efficiency, microhardness (MH), smear layer (SL) removal efficacy, and push-out bond strength (PBS) of AH plus sealer to canal dentin. Sixty single-rooted teeth were selected, disinfected, and categorized into four groups based on the type of disinfection. Following disinfection, a pair of samples were randomly selected and visualized under scanning electron microscope (SEM) for SL evaluation.

View Article and Find Full Text PDF

Superior vena cava obstruction following pericardial effusion absorption in the presence of a pericardial teratoma: a case report.

J Cardiothorac Surg

January 2025

Department of Cardiac Surgery, Children's Hospital Affiliated Shandong University Jinan Children's Hospital, No. 23976, Jingshi Road, Huaiyin District, Jinan City, Shandong Province, China.

Intrapericardial teratoma is a rare tumor that usually presents in neonates or during infancy because of the associated high degree of pericardial effusion, cardiac compression and severe respiratory distress. In this paper, we report a rare case of intrapericardial teratoma that was incidentally discovered in an infant with superior vena cava obstruction following pericardial effusion absorption. Echocardiography and thoracic computed tomography angiography revealed that the intrapericardial mass obviously suppressed the superior vena cava.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!