The utilisation of mechanical circulatory support devices in patients undergoing high-risk coronary artery bypass continues to increase. The Impella is a ventricular assist device commonly used in the setting of post-cardiotomy cardiogenic shock. This device can be implanted directly into the ascending aorta during open cardiac surgery. Device fracture is a documented complication of the Impella; however, the management of device fracture during direct explantation from an aortic graft has not yet been described. We report a case of Impella device fracture during its removal from a prosthetic aortic graft and discuss the management of this complication.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9848055 | PMC |
http://dx.doi.org/10.1093/jscr/rjac637 | DOI Listing |
Sci Rep
January 2025
Department of Oral Rehabilitation, the Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, 6997801, Israel.
Osseointegrated dental implants represent a successful treatment modality for partial and complete edentulism. However, concerns persist regarding their impact on adjacent natural teeth. Conflicting literature exists regarding complications such as caries, mobility, and fractures in neighboring teeth, with few studies comparing these effects with those observed in contralateral natural teeth.
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Northeast Health Wangaratta, VIC Australia.
Case: A 49-year-old gentleman sustained a closed, right tibia peri-implant fracture with a bent intramedullary nail. This resulted in a 17° valgus and 5° recurvatum deformity with fracture at the distal third of the tibial shaft. The patient underwent closed manipulation with an F-Tool and was reviewed by our unit over the following year.
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Morinomiya University of Medical Sciences, Graduate School of Health Sciences, Osaka, Japan.
Case: A 75-year-old woman underwent cruciate retaining total knee arthroplasty (TKA) for osteonecrosis of the knee, converted from unicompartmental arthroplasty due to an intraoperative medial tibial plateau fracture. Four years later, she experienced persistent knee pain. Computed tomography revealed tibial malalignments in 2 planes.
View Article and Find Full Text PDFJ Am Acad Orthop Surg
January 2025
From the Hawaii Permanente Medical Group, Kaiser Permanente, Honolulu, HI (Okike), the Department of Surgical Outcomes and Analysis, Kaiser Permanente, San Diego, CA (Prentice, Paxton, and Fasig), the San Francisco Orthopaedic Residency Program, San Francisco, CA (Shah), the Permanente Medical Group, Oakland, CA (Grimsrud), and the Washington Permanente Medical Group P.C, Seattle, WA (Chen).
Background: Cemented fixation is recommended in the hemiarthroplasty treatment of geriatric femoral neck fractures. Certain cemented stems have similarly designed "low-demand" counterparts, but it is unclear whether they yield comparable clinical outcomes. The purpose of this study was to evaluate the revision risk associated with two low-demand stems, Summit Basic (DePuy Synthes) and Versys LD/Fx (Zimmer Biomet), in comparison to their standard counterparts, Summit (DePuy Synthes) and Versys Advocate (Zimmer Biomet).
View Article and Find Full Text PDFJ Spine Surg
December 2024
Department of Neurosurgery, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
Atlantoaxial rotatory subluxation (AARS) in the adult population is primarily trauma-induced. Conservative and surgical treatments have both been used successfully in treating AARS. In cases where AARS cannot be reduced by conservative measures, open reduction and fusion is the conventional treatment approach.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!