Purpose: On the basis of the Thoracolumbar Injury Classification and Severity Score (TLICS), an modified TLICS classification system was presented, its reliability and repeatability were assessed, and the factors influencing classification consistency were examined.

Methods: Five spinal surgeons were chosen at random. The clinical data of 120 patients with thoracolumbar fractures admitted to the Department of Spine Surgery, Ningbo Sixth Hospital from December 2019 to June 2021 were categorized using the modified TLICS system. After 6 weeks, disrupt the order of data again. Using unweighted Cohen's kappa coefficients, the consistency of the modified TLICS system was assessed in five aspects: neurofunctional status, disc injury status, fracture morphology, posterior ligament complex (PLC) integrity, and treatment plan.

Results: In terms of reliability, the average kappa values for the subclasses of the modified TLICS system (neurofunctional status and disc injury status) were 0.920 and 0.815, respectively, reaching the category of complete confidence. Fracture morphology and treatment plan had average kappa values of 0.670 and 0.660, respectively, which were basically reliable. The average kappa value of PLC integrity was 0.453, which belonged to the category of moderate confidence. The average kappa coefficients of each subcategory (neurological status, disc injury status) had excellent consistency, and the kappa values were 0.936 and 0.879, respectively, which belonged to the completely credible category. The kappa values of fracture morphology and treatment plan repeatability were 0.772 and 0.749, respectively, reaching the basic credibility category. PLC integrity repeatability kappa value is low, 0.561, to moderate credibility category.

Conclusion: The modified TLICS system is intuitive and straightforward to understand. The examination of thoracolumbar fracture injuries is more exhaustive and precise, with excellent reliability and repeatability. The examination of neurological status and disc injury status is quite reliable and consistent. The consistency of fracture morphology is slightly poor, which is basically credible; the PLC integrity consistency is poor, reaching a reliability level of moderate, which may be associated with the subjectivity of clinical evaluation of PLC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9857768PMC
http://dx.doi.org/10.3389/fsurg.2022.1054031DOI Listing

Publication Analysis

Top Keywords

modified tlics
20
tlics system
16
status disc
16
disc injury
16
injury status
16
fracture morphology
16
plc integrity
16
average kappa
16
kappa values
16
reliability repeatability
12

Similar Publications

Study Design: Systematic Literature Review.

Objectives: To address whether TLICS or AOSpine is best used in clinical practice through assessment of interobserver and intraobserver reliability, agreement, and imaging modality performance.

Methods: This systematic literature review was reported in accordance with PRISMA 2020 guidelines.

View Article and Find Full Text PDF

Background And Objectives: The most common thoracolumbar trauma classification systems are the Thoracolumbar Injury Classification and Severity Score (TLICS) and the Thoracolumbar AO Spine Injury Score (TL AOSIS). Predictive accuracy of treatment recommendations is a historical limitation. Our objective was to validate and compare TLICS, TL AOSIS, and a modified TLICS (mTLICS) that awards 2 points for the presence of fractured vertebral body height loss >50% and/or spinal canal stenosis >50% at the fracture site.

View Article and Find Full Text PDF
Article Synopsis
  • This study aimed to evaluate the effectiveness of using inclined-long pedicle screws combined with interbody fusion for treating thoracolumbar fractures with disc injuries in 28 patients over a period of five years.
  • The patient group comprised 22 males and 6 females, with injuries primarily resulting from falls and traffic accidents; their spinal injuries were categorized using the ASIA scale.
  • The findings indicated that the surgery generally had a reasonable operation time and blood loss, with successful recovery and no major surgical complications reported.
View Article and Find Full Text PDF

Study Design: Reliability study utilizing 183 injury CT scans by 22 spine trauma experts with assessment of radiographic features, classification of injuries and treatment recommendations.

Objectives: To assess the reliability of the AOSpine TL Injury Classification System (TLICS) including the categories within the classification and the M1 modifier.

Methods: Kappa and Intraclass correlation coefficients were produced.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the feasibility of the modified thoracolumbar injury classification and severity score system in guiding clinical treatment.

Methods: A retrospective study was conducted on a cohort of 120 patients with thoracolumbar fractures who were admitted to the Department of Spinal Surgery at Ningbo Sixth Hospital between December 2019 and June 2021. The study population consisted of 68 males and 52 females, with an average age of 36.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!