Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acvd.2022.12.002DOI Listing

Publication Analysis

Top Keywords

pacemakers implantable
4
implantable cardiac
4
cardiac defibrillators
4
defibrillators fear
4
fear hackers?
4
hackers? cybersecurity
4
cybersecurity implantable
4
implantable electronic
4
electronic devices
4
pacemakers
1

Similar Publications

Objective: Phase angle (PhA) is a prognostic factor for predicting and monitoring geriatric syndromes. However, multiple factors associated with increased PhA values as an outcome remain unclear in the older population. This study aimed to examine the association of socio-demographic, anthropometric and behavioural factors with PhA among older Taiwanese adults.

View Article and Find Full Text PDF

Lower mini-sternotomy: an approach for treating all valvulopathies?

Ann Thorac Surg

December 2024

Sorbonne University, Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.

Background: Lower mini-sternotomy offers the advantage of providing excellent visualization of the 4 cardiac cavities, allowing surgical treatment of aortic, mitral and tricuspid valves as well as any intra-cavitary procedure. Technical issues, as well as safety and echocardiographic results of this approach, are lacking. The aim of this retrospective study was to describe outcomes of lower mini-sternotomy to treat valvulopathies and other intracardiac surgeries.

View Article and Find Full Text PDF

Minimizing for Maximum Benefit: An Illustrative Case-Series of Atrial Only Leadless Pacing.

Pacing Clin Electrophysiol

December 2024

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.

Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.

View Article and Find Full Text PDF

Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.

View Article and Find Full Text PDF

Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.

View Article and Find Full Text PDF