A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biofunctionalization of Porous Titanium Oxide through Amino Acid Coupling for Biomaterial Design. | LitMetric

Porous transition metal oxides are widely studied as biocompatible materials for the development of prosthetic implants. Resurfacing the oxide to improve the antibacterial properties of the material is still an open issue, as infections remain a major cause of implant failure. We investigated the functionalization of porous titanium oxide obtained by anodic oxidation with amino acids (Leucine) as a first step to couple antimicrobial peptides to the oxide surface. We adopted a two-step molecular deposition process as follows: self-assembly of aminophosphonates to titanium oxide followed by covalent coupling of Fmoc-Leucine to aminophosphonates. Molecular deposition was investigated step-by-step by Atomic Force Microscopy (AFM) and X-ray Photoemission Spectroscopy (XPS). Since the inherent high roughness of porous titanium hampers the analysis of molecular orientation on the surface, we resorted to parallel experiments on flat titanium oxide thin films. AFM nanoshaving experiments on aminophosphonates deposited on flat TiO indicate the formation of an aminophosphonate monolayer while angle-resolved XPS analysis gives evidence of the formation of an oriented monolayer exposing the amine groups. The availability of the amine groups at the outer interface of the monolayer was confirmed on both flat and porous substrates by the following successful coupling with Fmoc-Leucine, as indicated by high-resolution XPS analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9865921PMC
http://dx.doi.org/10.3390/ma16020784DOI Listing

Publication Analysis

Top Keywords

titanium oxide
16
porous titanium
12
molecular deposition
8
coupling fmoc-leucine
8
xps analysis
8
amine groups
8
oxide
6
titanium
5
biofunctionalization porous
4
oxide amino
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!