Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This systematic review aimed to determine the accuracy/stability of patient-specific osteosynthesis (PSI) in orthognathic surgery according to three-dimensional (3D) outcome analysis and in comparison to conventional osteosynthesis and computer-aided designed and manufactured (CAD/CAM) splints or wafers. The PRISMA guidelines were followed and six academic databases and Google Scholar were searched. Records reporting 3D accuracy/stability measurements of bony segments fixated with PSI were included. Of 485 initial records, 21 met the eligibility (566 subjects), nine of which also qualified for a meta-analysis (164 subjects). Six studies had a high risk of bias (29%), and the rest were of low or moderate risk. Procedures comprised either single-piece or segmental Le Fort I and/or mandibular osteotomy and/or genioplasty. A stratified meta-analysis including 115 subjects with single-piece Le Fort I PSI showed that the largest absolute mean deviations were 0.5 mm antero-posteriorly and 0.65° in pitch. PSIs were up to 0.85 mm and 2.35° more accurate than conventional osteosynthesis with CAD/CAM splint or wafer (p < 0.0001). However, the clinical relevance of the improved accuracy has not been shown. The literature on PSI for multi-piece Le Fort I, mandibular osteotomies and genioplasty procedure is characterized by high methodological heterogeneity and a lack of randomized controlled trials. The literature is lacking on the 3D stability of bony segments fixated with PSI.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9867342 | PMC |
http://dx.doi.org/10.3390/jpm13010125 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!