(1) Background: T1 mapping in magnetic resonance imaging (MRI) of the liver has been proposed to estimate liver function or to detect the stage of liver disease, among others. Thus far, the impact of intrahepatic fat on T1 quantification has only been sparsely discussed. Therefore, the aim of this study was to evaluate the potential of water-fat separated T1 mapping of the liver. (2) Methods: A total of 386 patients underwent MRI of the liver at 3 T. In addition to routine imaging techniques, a 3D variable flip angle (VFA) gradient echo technique combined with a two-point Dixon method was acquired to calculate T1 maps from an in-phase (T1_in) and water-only (T1_W) signal. The results were correlated with proton density fat fraction using multi-echo 3D gradient echo imaging (PDFF) and multi-echo single voxel spectroscopy (PDFF_MRS). Using T1_in and T1_W, a novel parameter FF_T1 was defined and compared with PDFF and PDFF_MRS. Furthermore, the value of retrospectively calculated T1_W (T1_W_calc) based on T1_in and PDFF was assessed. Wilcoxon test, Pearson correlation coefficient and Bland-Altman analysis were applied as statistical tools. (3) Results: T1_in was significantly shorter than T1_W and the difference of both T1 values was correlated with PDFF (R = 0.890). FF_T1 was significantly correlated with PDFF (R = 0.930) and PDFF_MRS (R = 0.922) and yielded only minor bias compared to both established PDFF methods (0.78 and 0.21). T1_W and T1_W_calc were also significantly correlated (R = 0.986). (4) Conclusion: T1_W acquired with a water-fat separated VFA technique allows to minimize the influence of fat on liver T1. Alternatively, T1_W can be estimated retrospectively from T1_in and PDFF, if a Dixon technique is not available for T1 mapping.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9858222PMC
http://dx.doi.org/10.3390/diagnostics13020201DOI Listing

Publication Analysis

Top Keywords

water-fat separated
12
separated mapping
8
mapping liver
8
fat fraction
8
mri liver
8
gradient echo
8
t1_w t1_w_calc
8
t1_in pdff
8
correlated pdff
8
liver
7

Similar Publications

This study aimed to investigate the cause of susceptibility underestimation in body quantitative susceptibility mapping (QSM) and propose a water/fat separate reconstruction to address this issue. A numerical simulation was conducted using conventional QSM with/without body masking. The conventional method with body masking underestimated the susceptibility across all regions, whereas the method without body masking estimated an equivalent value to the ground truth.

View Article and Find Full Text PDF

Purpose: To develop a novel imaging sequence that independently acquires water and fat images while being inherently insensitive to motion.

Methods: The new sequence, termed spectrally selective and interleaved water imaging and fat imaging (siWIFI), uses a narrow bandwidth RF pulse for selective excitation of water and fat separately. The interleaved acquisition method ensures that the obtained water and fat images are inherently coregistered.

View Article and Find Full Text PDF

Left atrial (LA) epicardial adipose tissue (EAT) and wall fibrosis are both proven to contribute to the pathogenesis and progression of atrial fibrillation (AF). The theory of LA wall fibrosis induction by local EAT infiltration, paracrine secretions, and activation of the inflammatory process is strongly advocated, but the imaging evidence for anatomical proximity of the two tissue types and its association to AF stage is lacking. Accordingly, the aim of the study was to analyse the spatial overlap between LA EAT and adjacent wall fibrosis using 3D Dixon water-fat separated late gadolinium enhancement (LGE-Dixon) MRI and correlate the findings with the clinical AF stage.

View Article and Find Full Text PDF

Purpose: DWI is an important contrast for prostate MRI to enable early and accurate detection of cancer. This study introduces a Dixon 3-shot-EPI protocol with structured low-rank reconstruction for navigator-free DWI. The aim is to overcome the limitations of single-shot EPI (ssh-EPI), such as geometric distortions and fat signal interference, while addressing the motion-induced phase variations of multishot EPI and simultaneously allowing water/fat separation.

View Article and Find Full Text PDF

Context: Bone marrow adiposity (BMAT) alterations in patients with type 2 diabetes mellitus (T2DM) may contribute to adverse bone effects.

Objective: Characterization of BMAT content and composition in patients with well-controlled T2DM.

Methods: This cross-sectional study included 2 groups of postmenopausal women: one with T2DM and the other without.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!