AI Article Synopsis

  • The text presents a new method for calculating the noise spectrum of transport current in interacting mesoscopic systems using a time-nonlocal quantum master equation.
  • By introducing specific current-related density operators, the method achieves an efficient time-local equation of motion to capture emission and absorption details.
  • The approach is validated with double quantum dots systems, showing accurate results when the system-reservoir coupling is less than the temperature.

Article Abstract

Within the time-nonlocal quantum master equation description, we develop an efficient method for calculating the noise spectrum of transport current through interacting mesoscopic systems. By introducing proper current-related density operators, we propose a practical and very efficient time-local equation of motion implementation to compute the noise spectrum, which contains the full information of emission and absorption. We obtain an analytical expression to characterize the nonequilibrium transport including Coulomb interaction and memory effect. We demonstrate the proposed method with double quantum dots systems and find good agreement with the exact results, whenever the system-reservoir coupling is smaller than the temperature.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevE.106.064130DOI Listing

Publication Analysis

Top Keywords

noise spectrum
12
quantum master
8
spectrum transport
8
transport current
8
memory-effect-preserving quantum
4
master equation approach
4
equation approach noise
4
current time-nonlocal
4
time-nonlocal quantum
4
master equation description
4

Similar Publications

Diabetes is a growing health concern in developing countries, causing considerable mortality rates. While machine learning (ML) approaches have been widely used to improve early detection and treatment, several studies have shown low classification accuracies due to overfitting, underfitting, and data noise. This research employs parallel and sequential ensemble ML approaches paired with feature selection techniques to boost classification accuracy.

View Article and Find Full Text PDF

Comparison of ZnS(Ag) Scintillator and Proportional Counter Tube for Alpha Detection in Thin-Layer Chromatography.

Pharmaceuticals (Basel)

December 2024

Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technical University Dresden, Fetscherstr. 74, 01307 Dresden, Germany.

(1) : Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of Pb- and Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the Pb/Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) : The routine alpha detection on thin-layer chromatograms (TLC) of Pb- and Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) : For Ac, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken.

View Article and Find Full Text PDF

Spectrum sensing is recognized as a viable strategy to alleviate the scarcity of spectrum resources and to optimize their usage. In this paper, considering the time-varying characteristics and the dependence on various timescales within a time series of samples composed of in-phase (I) and quadrature (Q) component signals, we propose a multi-scale time-correlated perceptual attention model named MSTC-PANet. The model consists of multiple parallel temporal correlation perceptual attention (TCPA) modules, enabling us to extract features at different timescales and identify dependencies among features across various timescales.

View Article and Find Full Text PDF

A solution to address the issues of environmental light interference in Remote Photoplethysmography (rPPG) methods is proposed in this paper. First, signals from the face's region of interest (ROI) and background noise signals are simultaneously collected, and the two signals are processed by a differential to obtain a more accurate rPPG signal. This method effectively suppresses background noise and enhances signal quality.

View Article and Find Full Text PDF

Pulsation noise in the piping system generated by the excitation of the pump source seriously affects the reliability of the pipeline system and mechanical equipment. The active noise control can effectively suppress the low-frequency noise in the liquid-filled pipeline. Active control methods with intrusive secondary sources generally use dynamic pressure sensors or hydrophones to collect signals, which destroy the structure of the pipe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!