A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical Evaluation of Reading Performance in Refractive Lens Exchange With a Diffractive Continuous-Range-of-Vision Intraocular Lens. | LitMetric

Purpose: Evaluation of reading performance with a novel presbyopia correcting intraocular lens (IOL) in refractive lens exchange using an electronic reading desk.

Design: Prospective interventional before-and-after clinical study.

Methods: In total, 56 eyes of 28 patients were included. Bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Surgical Vision) during a bilateral delayed sequential refractive lens exchange procedure. Uncorrected and distance corrected reading acuity, reading distance, reading speed, and the smallest print size that could be read effectively at a set (40 cm/80 cm) and subjectively chosen near and intermediate distance were assessed using the Salzburg Reading Desk preoperatively and 6 months after surgery.

Results: Uncorrected near reading acuity increased from 0.61 ± 0.16 logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.05 ± 0.09 logMAR postoperatively at the set near distance (40 cm) and from 0.60 ± 0.11 logMAR to 0.07 ± 0.08 logMAR at the subjectively preferred distance (39.6 ± 5.3 cm and 37.7 ± 4.3 cm). Uncorrected intermediate reading acuity was 0.39 ± 0.19 logMAR preoperatively and 0.08 ± 0.07 logMAR postoperatively at the set intermediate distance (80 cm) and 0.43 ± 0.21 logMAR preoperatively and 0.07 ± 0.08 logMAR postoperatively at the preferred intermediate distance (73.5 ± 9.5 cm and 73.3 ± 5.9 cm).

Conclusions: Uncorrected intermediate and near reading function considerably improved after bilateral implantation of the TECNIS Synergy IOL. Patients preferred a closer near and intermediate distance to the set distances. However, reading function was comparable for the set and subjectively preferred distances.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2023.01.011DOI Listing

Publication Analysis

Top Keywords

intermediate distance
16
refractive lens
12
lens exchange
12
reading acuity
12
logmar preoperatively
12
logmar postoperatively
12
reading
11
evaluation reading
8
reading performance
8
intraocular lens
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!