A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surgical Outcomes at a Single Institution of Infrapubic Insertion of Malleable Penile Prosthesis in Transmen. | LitMetric

Objective: To describe our technique for the infrapubic approach for malleable penile prosthesis (MPP) insertion after phalloplasty in transgender men and review surgical outcomes.

Methods: The infrapubic prosthesis insertion technique involves a horizontal incision anterior to the pubic symphysis, allowing dissection of the neophallus tract and anchor site on the pubic symphysis. Surgical outcomes by a single surgeon using a Spectra or Genesis MPP between October 2017 and May 2022 were retrospectively reviewed. Complications were categorized into erosions, infections, device detachment, device malposition, pain or activity limitation, urethral injury, and flap loss. Implant survival kinetics were assessed by evaluating time to surgical revision.

Results: Forty patients underwent infrapubic MPP insertion; 35 patients had a prior radial forearm free flap (RFFF) and 5 had a prior anterolateral thigh flap (ALT) phalloplasty. Of 30 patients who maintained follow-up, mean follow-up was 34.9 months. Complications were not mutually exclusive, with 7 implant detachments from the anchor site, 3 malpositions, 2 with pain/activity limitation, and 1 infection. Surgical revision was required in 12/30 patients (40%). There were no neophallus erosions, flap loss, nor urethral injuries. More complications occurred with the Spectra (9/17 or 53%) than the Genesis MPP (3/13 or 23%), but this was not statistically significant (P = .10).

Conclusion: Infrapubic insertion in transmen after phalloplasty using commercially available MPPs is safe compared with other post-phalloplasty penile prosthesis insertion techniques, with similarly high surgical revision rates. Further study of techniques is needed to improve outcomes after penile prosthesis insertion in transmen.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2023.01.001DOI Listing

Publication Analysis

Top Keywords

penile prosthesis
16
prosthesis insertion
12
surgical outcomes
8
outcomes single
8
infrapubic insertion
8
malleable penile
8
mpp insertion
8
pubic symphysis
8
anchor site
8
genesis mpp
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!