The sterile insect technique (SIT) is based on the inundatory field release of a target pest following their reproductive sterilization via exposure to radiation. Until recently, gamma irradiation from isotopic sources has been the most widely used in SIT programs. As isotopic sources are becoming increasingly expensive, especially for small programs, and regulations surrounding their procurement and shipment increasingly strict, irradiation capacity is one of the limiting factors in smaller or newly developing SIT projects. For this reason, the possibility of using X-ray irradiators has been evaluated in the recent decade. The availability of "off-the-shelf" blood X-ray irradiators that meet the technical requirements for insect irradiation can provide irradiation capacity for those SIT projects in which the acquisition of gamma ray irradiators is not feasible. Following the recent technical characterization of a Raycell MK2 X-ray blood irradiator, it was found in this study, that MK2 instruments were suitable for the sterilization of fruit flies, tsetse flies and mosquitoes, inducing comparable, even slightly higher, sterility levels compared to those achieved by gamma ray irradiation. This, together with its estimated processing efficiency, shows that MK2 irradiators are suitable for small- to mid-sized SIT programs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861990PMC
http://dx.doi.org/10.3390/insects14010092DOI Listing

Publication Analysis

Top Keywords

raycell mk2
8
blood x-ray
8
sterile insect
8
insect technique
8
fruit flies
8
flies tsetse
8
tsetse flies
8
flies mosquitoes
8
isotopic sources
8
sit programs
8

Similar Publications

An area-wide integrated pest management strategy with a sterile insect technique (SIT) component requires a radiation source for the sterilisation of male insects. Self-contained gamma irradiators, which were exclusively used in past SIT programmes, are now facing increasing constraints and challenges due to stringent regulations. As a potential alternative, new generation high output X-ray irradiators have been proposed.

View Article and Find Full Text PDF

Absorbed dose evaluation of a blood irradiator with alanine, TLD-100 and ionization chamber.

Appl Radiat Isot

October 2023

Unit of Medical Physics and Radioprotection, A.O.U Policlinico Federico II, 80131, Naples, Italy.

Irradiation of blood bags using X-ray irradiators and dosimetry services are required to ensure uniform dose levels in the range 25-50 Gy to prevent Transfusion Associated Graft versus Host Disease (TA-GvHD). An absorbed dose characterization of a Raycell MK2 X-Irradiator was performed using three different dosimetric systems. Results showed a dosimetric accuracy of the ionization chamber together with the Alanine dosimeter.

View Article and Find Full Text PDF

The sterile insect technique (SIT) is based on the inundatory field release of a target pest following their reproductive sterilization via exposure to radiation. Until recently, gamma irradiation from isotopic sources has been the most widely used in SIT programs. As isotopic sources are becoming increasingly expensive, especially for small programs, and regulations surrounding their procurement and shipment increasingly strict, irradiation capacity is one of the limiting factors in smaller or newly developing SIT projects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!