Background: Current therapeutic strategies in multiple sclerosis (MS) target neurodegeneration. However, the integration of atrophy measures into the clinical scenario is still an unmet need.

Purpose: To compare methods for whole-brain and gray matter (GM) atrophy measurements using the Italian Neuroimaging Network Initiative (INNI) dataset.

Study Type: Retrospective (data available from INNI).

Population: A total of 466 patients with relapsing-remitting MS (mean age = 37.3 ± 10 years, 323 women) and 279 healthy controls (HC; mean age = 38.2 ± 13 years, 164 women).

Field Strength/sequence: A 3.0-T, T1-weighted (spin echo and gradient echo without gadolinium injection) and T2-weighted spin echo scans at baseline and after 1 year (170 MS, 48 HC).

Assessment: Structural Image Evaluation using Normalization of Atrophy (SIENA-X/XL; version 5.0.9), Statistical Parametric Mapping (SPM-v12); and Jim-v8 (Xinapse Systems, Colchester, UK) software were applied to all subjects.

Statistical Tests: In MS and HC, we evaluated the intraclass correlation coefficient (ICC) among FSL-SIENA(XL), SPM-v12, and Jim-v8 for cross-sectional whole-brain and GM tissue volumes and their longitudinal changes, the effect size according to the Cohen's d at baseline and the sample size requirement for whole-brain and GM atrophy progression at different power levels (lowest = 0.7, 0.05 alpha level). False discovery rate (Benjamini-Hochberg procedure) correction was applied. A P value <0.05 was considered statistically significant.

Results: SPM-v12 and Jim-v8 showed significant agreement for cross-sectional whole-brain (ICC = 0.93 for HC and ICC = 0.84 for MS) and GM volumes (ICC = 0.66 for HC and ICC = 0.90) and longitudinal assessment of GM atrophy (ICC = 0.35 for HC and ICC = 0.59 for MS), while no significant agreement was found in the comparisons between whole-brain and GM volumes for SIENA-X/XL and both SPM-v12 (P = 0.19 and P = 0.29, respectively) and Jim-v8 (P = 0.21 and P = 0.32, respectively). SPM-v12 and Jim-v8 showed the highest effect size for cross-sectional GM atrophy (Cohen's d = -0.63 and -0.61). Jim-v8 and SIENA(XL) showed the smallest sample size requirements for whole-brain (58) and GM atrophy (152), at 0.7 power level.

Data Conclusion: The findings obtained in this study should be considered when selecting the appropriate brain atrophy pipeline for MS studies.

Evidence Level: 4.

Technical Efficacy: Stage 1.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.28616DOI Listing

Publication Analysis

Top Keywords

multiple sclerosis
8
spin echo
8
spm-v12 jim-v8
8
atrophy
5
methods brain
4
brain atrophy
4
atrophy quantification
4
quantification multiple
4
sclerosis application
4
application multicenter
4

Similar Publications

Drug Development.

Alzheimers Dement

December 2024

Dementia Research Centre, UCL Queen Square Institute of Neurology, London, United Kingdom.

The recent positive phase 3 clinical trials of new treatments and their licensing and roll-out in the US and other countries represents a major turning point in Alzheimer's disease research. As has been the case with many other diseases, e.g.

View Article and Find Full Text PDF

Background: The PANORAMA survey aimed to assess current treatment practice for individuals with new diagnoses of relapsing-remitting multiple sclerosis (RRMS) in the United Kingdom and to explore variations in treatment approaches with an emphasis on escalation vs early high-efficacy treatment (HET) and treatment goals.

Methods: Health care professionals (HCPs) from the UK treating patients with RRMS took part in interviews facilitated by a structured questionnaire. Data were analyzed descriptively using quantitative or qualitative methods, as appropriate.

View Article and Find Full Text PDF

Primary progressive multiple sclerosis (PPMS) affects 10-15% of multiple sclerosis patients and presents significant variability in the rate of disability progression. Identifying key biological features and patients at higher risk for fast progression is crucial to develop and optimize treatment strategies. Peripheral blood cell transcriptome has the potential to provide valuable information to predict patients' outcomes.

View Article and Find Full Text PDF

Neuromyelitis optica spectrum disorder (NMOSD) includes conditions with autoimmune genesis, which are manifested by attacks of optic neuritis (ON) and transverse myelitis (TM), and also express aquaporin 4 (NMO-IgG) or myelin oligo-endocytic glycoprotein (MOGAb) antibodies. In rare cases, the disease may also have a clinical presentation with only TM, without ON or with ON, without TM. These conditions are also included in the spectrum.

View Article and Find Full Text PDF

Factors associated with self-reported work ability among people with multiple sclerosis in Sweden.

Mult Scler J Exp Transl Clin

January 2025

Division of Insurance Medicine, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.

Background: Work ability index (WAI) is an instrument that measures work ability in workplace surveys and health examinations in occupational health and research. It has been used in different population groups. But research is limited among people with multiple sclerosis (PwMS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!