Background: Dual energy X-ray absorptiometry (DXA) is often used as a criterion measure in body composition research and in clinical settings for the estimate of body fat percent (%Fat). The accuracy of DXA for predicting %Fat has primarily been conducted in non-Hispanic populations.

Aim: The purpose of this study was to determine the agreement of DXA-derived %Fat in Hispanic and non-Hispanic Caucasian adults.

Methods: The sample consisted of Hispanic males (n = 96) and females (n = 102) and non-Hispanic Caucasian males (n = 145) and females (n = 161). The %Fat of a whole-body DXA scan was compared against a criterion 4-compartment (4C) model via constant error (CE = DXA - 4C model) and 95% limits of agreement. Also, a 2 × 2 factorial ANOVA, using CE as a dependent variable, was conducted to examine the main and interaction effects of sex and ethnicity.

Results: When compared to the 4C model, DXA overestimated %Fat by 4.0% in Hispanics and 5.5% in non-Hispanic Caucasians (all p < 0.05). The 95% limits of agreement ranged from ±5.5% to ±5.9% for all group comparisons. The 2 × 2 factorial ANOVA indicated the CE was greater in non-Hispanic Caucasians than Hispanics (CE difference = 1.5%; p < 0.05).

Conclusion: Our findings revealed that DXA significantly overestimates %Fat in both populations (Hispanics and non-Hispanic Caucasians), when compared to a 4C model, regardless of sex (male or female). However, the error is more profound in non-Hispanic Caucasian adults. It is worth nothing that DXA may be useful for tracking changes in body composition that occur throughout a lifestyle intervention. Nonetheless, practitioners should be aware that the estimate of %Fat from DXA may be larger than the actual values obtained from a 4C model.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10364970PMC
http://dx.doi.org/10.1016/j.clnesp.2022.12.012DOI Listing

Publication Analysis

Top Keywords

dual energy
8
energy x-ray
8
x-ray absorptiometry
8
non-hispanic caucasians
8
non-hispanic caucasian
8
non-hispanic
5
%fat
5
absorptiometry produces
4
produces larger
4
larger measurement
4

Similar Publications

Head and neck automatic multi-organ segmentation on Dual-Energy Computed Tomography.

Phys Imaging Radiat Oncol

October 2024

Université Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.

Background And Purpose: Deep-learning-based automatic segmentation is widely used in radiation oncology to delineate organs-at-risk. Dual-energy CT (DECT) allows the reconstruction of enhanced contrast images that could help with manual and auto-delineation. This paper presents a performance evaluation of a commercial auto-segmentation software on image series generated by a DECT.

View Article and Find Full Text PDF

Activity-Stability Relationships in Oxygen Evolution Reaction.

ACS Mater Au

January 2025

Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.

The oxygen evolution reaction (OER) is a critical process in various sustainable energy technologies. Despite substantial progress in catalyst development, the practical application of OER catalysts remains hindered by the ongoing challenge of balancing high catalytic activity with long-term stability. We explore the inverse trends often observed between activity and stability, drawing on key insights from both experimental and theoretical studies.

View Article and Find Full Text PDF

Background: Osteoporosis is the leading cause of vertebral fractures. Dual-energy X-ray absorptiometry (DXA) and radiographs are traditionally used to detect osteoporosis and vertebral fractures/deformities. Magnetic resonance imaging (MRI) can be utilized to detect the relative severity of vertebral deformities using three-dimensional information not available in traditional DXA and lateral two-dimensional radiography imaging techniques.

View Article and Find Full Text PDF

The immense energy footprint of desalination and brine treatment is a barrier to a green economy. Interfacial evaporation (IE) offers a sustainable approach to water purification by efficient energy conversion. However, conventional evaporators are susceptible to fluctuations in solar radiation and the salinity of handling liquid.

View Article and Find Full Text PDF

The plastic waste accumulation requires facile yet effective solutions. Currently mechanical recycling typically leads to downcycling, while the environmental footprint of chemical recycling is often unacceptable. Here, we introduce a dual circularity concept, where rational molecular design paves the way for complementary closed-loop mechanical and chemical recyclability under mild conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!