N-nitrosamines (NA) impurities have unexpectedly been found in sartan products, angiotensin II receptor antagonists that are used to control hypertension, representing an urgent concern for industry, global regulators and for the patients. In this study, an HPLC-MS/MS method was developed and validated for the quantification of six NA (N-nitrosodimethylamine, N-Nitroso-N-methyl-4-aminobutyric acid, N-Nitrosodiethylamine, N-ethyl-N-nitroso-2-propanamine, N-nitroso-diisopropylamine and N-nitroso-di-n-butylamine) in losartan, valsartan, olmesartan, irbesartan, candesartan and telmisartan products. The method was validated in terms of sensitivity, linearity, accuracy, precision, robustness and stability. The limits of quantification were 100, 31.25, 250, 33, 312.5 and 125 µg kg in losartan, valsartan, olmesartan, irbesartan, candesartan and telmisartan samples, respectively, which met the sensitivity requirements for the limits set by Food and Drug Administration of the United States. The standard curves showed good linearity. The recoveries ranged from 93.06 to 102.23% in losartan matrix, 83 to 85.9% in valsartan, 96.1 to 101.2% in olmesartan, 89.2 to 97.5% in irbesartan, 93.4 to 132.0% in candesartan and 62.3 to 106.2% in telmisartan matrix. The other parameters met the validation criteria, the good sensitivity and precision, high accuracy and simple and fast analysis provides a reliable method for quality control of NA in sartan pharmaceutical products. The developed method was successfully applied for the determination of N-nitrosamines in 71 sartan products marketed in Brazil.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.xphs.2023.01.005DOI Listing

Publication Analysis

Top Keywords

n-nitrosamines sartan
8
sartan pharmaceutical
8
pharmaceutical products
8
products marketed
8
marketed brazil
8
sartan products
8
losartan valsartan
8
valsartan olmesartan
8
olmesartan irbesartan
8
irbesartan candesartan
8

Similar Publications

Article Synopsis
  • The study investigates the presence of nitrosamine-related impurities and AZBT in sartan medications, classifying them as human mutagens and carcinogens based on long-term treatment effects.
  • A new, efficient method was developed for simultaneous quantification of these impurities using reversed-phase liquid chromatography combined with tandem mass spectrometry.
  • The method showed high extraction efficiency, wide linear range, and strong recovery rates, and was applied to analyze 16 losartan samples, finding AZBT in some but no nitrosamine impurities in any.
View Article and Find Full Text PDF

N-nitrosamines (NAs) are prevalent mutagenic impurities in various consumer products. Their discovery in valsartan-containing medicines in 2018 prompted global regulatory agencies to set guidelines on their presence and permissible levels in pharmaceuticals. In order to determine the NAs content in medicines, efficient and sensitive analytical methods have been developed based on mass spectrometry techniques.

View Article and Find Full Text PDF

Background: Angiotensin-converting enzyme inhibitors (ACE-I) and their pharmacologically related sartans have been associated with an increased cancer incidence in several clinical observations. In 2018, sartans were revealed as being significantly contaminated with nitrosamines. Nitrosamines are potent human mutagens that can be formed ex vivo and, more concerningly, also in vivo from nitrosatable drug precursors.

View Article and Find Full Text PDF

Simultaneous determination of low molecular weight nitrosamines in pharmaceutical products by fast gas chromatography mass spectrometry.

J Chromatogr A

October 2023

Drug Substance Analytical Development Division, Egis Pharmaceuticals PLC, Keresztúri út 30-38, Budapest H-1106, Hungary.

Control of N-nitrosamines has been in the focus of health authorities in recent years because many of these compounds are probable human carcinogens. In July 2018 the U.S.

View Article and Find Full Text PDF

The development of a fast, cost-effective, and efficient microextraction by packed sorbent setup was achieved by combining affordable laboratory-repackable devices of microextraction with a high-throughput cartesian robot. This setup was evaluated for the development of an analytical method to determine N-nitrosamines in losartan tablets. N-nitrosamines pose a significant concern in the pharmaceutical market due to their carcinogenic risk, necessitating their control and quantification in pharmaceutical products.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!