Prognostic Value of Baseline Tricuspid Annular Plane Systolic Excursion to Pulmonary Artery Systolic Pressure Ratio in Mitral Transcatheter Edge-to-Edge Repair.

J Am Soc Echocardiogr

Department of Cardiology, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California; David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California. Electronic address:

Published: April 2023

Background: A surrogate of right ventricular-pulmonary arterial coupling, the ratio of tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) has been associated with outcomes across a wide range of cardiac pathologies and interventions. The aim of this study was to assess the prognostic significance of baseline TAPSE/PASP ratio in patients undergoing mitral transcatheter edge-to-edge repair.

Methods: This was a single-center, retrospective analysis encompassing 448 days (interquartile range, 86-958 days) of follow-up after 707 consecutive isolated, first-time mitral transcatheter edge-to-edge repair procedures. Stratified by the cohort's median TAPSE/PASP ratio of 0.37 mm/mm Hg, eligible cases were examined for the occurrence of all-cause mortality and heart failure hospitalization.

Results: Patients with low TAPSE/PASP ratios exhibited a greater prevalence of functional mitral regurgitation, a higher burden of comorbidities, and worse clinical and echocardiographic indices of cardiac function, as well as an attenuated rate of technical success. After the procedure, they experienced similar 1-month and 1-year improvement in mitral regurgitation grade and functional status but higher rates of death, heart failure hospitalizations, and the composite of both at all time points explored (1 year, 15.3% vs 7.6%, 20.7% vs 10.2%, and 32.3% vs 16.1%, respectively; P < .001 for all). Lower TAPSE/PASP ratio was independently associated with a higher risk for the 1-year combined end point of death or heart failure hospitalizations (hazard ratio, 2.84; 95% CI, 1.09-7.43; P = .033). A novel TAPSE/PASP-MitraScore risk model showed a better discriminative property than currently validated scores. Subgroup analysis produced similarly significant observations solely in patients with functional mitral regurgitation (n = 383 [54.2%]), which remained when using subgroup-specific medians of the baseline TAPSE/PASP ratio.

Conclusions: A low TAPSE/PASP ratio before mitral transcatheter edge-to-edge repair identifies higher risk patients and predicts a less favorable outcome after the procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2022.12.026DOI Listing

Publication Analysis

Top Keywords

mitral transcatheter
12
transcatheter edge-to-edge
12
tricuspid annular
8
annular plane
8
plane systolic
8
systolic excursion
8
pulmonary artery
8
artery systolic
8
systolic pressure
8
edge-to-edge repair
8

Similar Publications

Background: Mitral regurgitation (MR) is a common valvular disorder linked to high morbidity and mortality. For patients unsuitable for surgery, transcatheter mitral edge-to-edge repair (TEER) with the MitraClip G4 system offers an alternative. This study aims to evaluate procedural, echocardiographic, functional, and quality of life (QoL) outcomes in patients who underwent TEER with the MitraClip G4 system, along with possible predictors of New York Heart Association (NYHA) class I at 30 days and at 1 year.

View Article and Find Full Text PDF

Objective: Percutaneous vegetation debulking has been reported to treat tricuspid valve infective endocarditis (TVIE), but data on feasibility compared with conventional surgical strategies are limited. We aimed to compare short-term outcomes of suction debulking with partial venovenous bypass to conventional open surgery in this population.

Methods: This was a single-center, retrospective study that included all patients with isolated TVIE who underwent suction debulking with partial venovenous bypass or tricuspid valve surgery between January 2010 and December 2022.

View Article and Find Full Text PDF

Background: Treatment of residual mitral regurgitation (MR) with different percutaneous devices after transcatheter edge-to-edge repair (TEER) has been reported as an alternative option to reclipping or surgery. This review aims at describing the different transcatheter strategies available and their results when managing residual MR after TEER.

Methods: A literature search was undertaken across Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases, to identify article reporting patients with post-TEER residual MR managed by a transcatheter approach that did not involve only the implantation of new clips.

View Article and Find Full Text PDF

Background: Right ventricular (RV) function has a well-established prognostic role in patients with severe mitral regurgitation (MR) undergoing transcatheter edge-to-edge repair (TEER) and is typically assessed using echocardiography-measured tricuspid annular plane systolic excursion. Recently, a deep learning model has been proposed that accurately predicts RV ejection fraction (RVEF) from 2-dimensional echocardiographic videos, with similar diagnostic accuracy as 3-dimensional imaging. This study aimed to evaluate the prognostic value of the deep learning-predicted RVEF values in patients with severe MR undergoing TEER.

View Article and Find Full Text PDF

Outcomes of a transapical edge-to-edge repair system in secondary mitral regurgitation.

J Invasive Cardiol

January 2025

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University; NHC Key Laboratory of Ischemic Heart Diseases; Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences; National Clinical Research Center for Interventional Medicine, Shanghai, China.

Objectives: The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.

Methods: The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers.

View Article and Find Full Text PDF