A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of scattered radiation dose for radiological staff during portable chest examinations of COVID-19 patients. | LitMetric

The COVID-19 pandemic has resulted in a large increase in the number of patients admitted to hospitals. Radiological technologists (RTs) are often required to perform portable chest X-ray radiography on these patients. Normally, when performing a portable X-ray, radiation protection equipment is critical as it reduces the scatter radiation dose to hospital workers. However, during the pandemic, the use of a lead shield caused a heavy weight burden on workers who were responsible for a large number of patients. This study aimed to investigate scatter radiation doses received at various distances, directions, and positions. Radiation measurements were performed using the PBU-60 whole body phantom to determine scatter radiation doses at 100-200 cm and eight different angles around the phantom. The tests were conducted with and without lead shielding. Additionally, the doses were compared using the paired t test (p < 0.005) to determine suitable positions for workers who did not wear lead protection that adhered to radiation safety requirements. Scatter radiation doses of all 40 tests showed a highest and lowest value of 1285.5 nGy at 100 cm in the anteroposterior (AP) semi upright position and 134.7 nGy at 200 cm in the prone position, respectively. Correlation analysis between the dosimeter measurement and calculated inverse square law showed good correlation, with an R value of 0.99. Without lead shielding, RTs must stay at a distance greater than 200 cm from patients for both vertical and horizontal beams to minimize scatter exposure. This would allow for an alternative way of performing portable chest radiography for COVID-19 patients without requiring lead shielding.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9851108PMC
http://dx.doi.org/10.1007/s12194-023-00698-2DOI Listing

Publication Analysis

Top Keywords

scatter radiation
12
radiation dose
8
portable chest
8
number patients
8
radiation doses
8
radiation
6
determination scattered
4
scattered radiation
4
dose radiological
4
radiological staff
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!