Background: The need for permanent pacemaker (PPM) implantation is a common complication after transcatheter aortic valve replacement (TAVR). Deep implantation position is a risk factor for PPM implantation. Thus, in the field of self-expandable (SE) transcatheter heart valves (THV) cusp overlap projection (COP) technique was implemented to reduce parallax, allowing a more precise guidance of implantation depth.
Aims: This meta-analysis aims to report the outcome of patients undergoing TAVR with SE THV using COP versus conventional implantation technique (CIT).
Methods: Systematical search in MEDLINE and EMBASE yielded five observational controlled studies comparing both implantation techniques for the SE Evolut prosthesis (Medtronic Intern. Ltd., CA, USA) and fulfilling the inclusion criteria for meta-analysis.
Results: Totally, 1227 patients were included, comprising 641 who underwent COP and 586 CIT TAVR. Incidence of post-procedural need for PPM implantation was significantly lower in COP group (9.8% vs 20.6%; OR = 0.43; p < 0.00001). This was accompanied by significantly higher implantation position in COP group (mean difference distance from distal end of the intraventricular portion of the THV to the non-coronary cusp (NCC): - 1.03 mm; p = 0.00001). Incidence of new-onset left bundle branch block did not differ. Regarding procedural and 30-day mortality, technical success, post-procedural aortic regurgitation, and rates of multiple device implantation, no difference between COP and CIT was found.
Conclusion: COP is an effective and safe implantation technique to reduce the need for a permanent pacemaker implantation during TAVR with SE Evolut prosthesis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10160159 | PMC |
http://dx.doi.org/10.1007/s00392-022-02150-8 | DOI Listing |
J Multidiscip Healthc
January 2025
Nursing Department, Hasan Sadikin General Hospital, Bandung, West Jawa, Indonesia.
Background: Permanent Pacemaker (PPM) implantation is essential in treating cardiac arrhythmias and conduction disorders, especially in patients with heart failure. Although PPM has been proven to improve quality of life and prolong life expectancy in patients with cardiac conduction disorders, post implantation complications still often occur.
Purpose: This study aimed to identify types of complications and associated predictors in patients undergoing PPM implantation.
Cureus
December 2024
Interventional Radiology, St Mary's Hospital, Waterbury, USA.
Superior vena cava (SVC) syndrome is a result of impaired blood flow from the SVC to the right atrium, leading to venous congestion in the head and neck. It can be caused by clotting disorders or compressive tumors of the head and neck but has become more prevalent in the setting of implantable devices such as pacemakers. As such, managing these patients can present challenges for physicians who have to account for SVC syndrome as well as their underlying condition requiring an implantable cardiac device.
View Article and Find Full Text PDFHeart Rhythm O2
December 2024
Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer Sheva, Israel.
Background: Transcatheter aortic valve replacement (TAVR) has revolutionized the management of aortic stenosis and has become the standard of care across a broad spectrum of patients with aortic stenosis. However, it is still associated with high incidence of conduction abnormalities, particularly new left bundle branch block (LBBB). Management of these patients remains a challenge.
View Article and Find Full Text PDFOpen Heart
January 2025
Department of Cardiology, Inserm U1096, Univ Rouen Normandie, CHU Rouen, Rouen, France
Introduction: Conductive disturbances requiring permanent pacemaker (PPM) implantation remain a major concern after transcatheter aortic valve implantation (TAVI).
Aims: To assess the impact of aortic valve calcium score (AVCS) on conductive disturbances requiring PPM after TAVI.
Methods: All patients who underwent TAVI with accessible AVCS from the preprocedural CT scan report were included in this retrospective single-centre study.
JACC Cardiovasc Interv
December 2024
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.
Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.
Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.