Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9842080 | PMC |
http://dx.doi.org/10.4103/ija.ija_657_22 | DOI Listing |
JA Clin Rep
December 2024
Department of Anesthesiology, Yokohama Municipal Citizen's Hospital, Yokohama, Japan.
Background: The standard of care for placement of a central venous catheter (CVC) includes a real-time ultrasound (US)-guided technique. We describe a rare case in which the guidewire penetrated the posterior wall of the vessel, forming a knot, which precluded simple removal. This occurred despite the procedure being performed under real-time US guidance.
View Article and Find Full Text PDFPaediatr Anaesth
January 2025
Department of Anesthesiology, Shenzhen Children's Hospital, Shenzhen, China.
Oper Orthop Traumatol
December 2024
Klinik für Orthopädie und Unfallchirurgie, Martin-Luther-Krankenhaus Berlin, Caspar Theyss Str. 27-33, Berlin, Deutschland.
Objective: Replacement of superficial medial collateral ligament (sMCL) and posterior oblique ligament (POL) with an allograft.
Indications: Chronic 3° isolated medial instability and combined anteromedial or posteromedial instability.
Contraindications: Infection, open growth plates, restricted range of motion (less than E/F 0-0-90°).
Front Cardiovasc Med
July 2023
Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdańsk, Gdańsk, Poland.
A 25-year-old female with idiopathic pulmonary arterial hypertension (PAH), who had a Hickman catheter implanted for continuous intravenous epoprostenol infusion, was admitted to the clinic after inadvertently cutting the catheter with nail scissors during a routine dressing change. Approximately 7 cm of the external segment of the Hickman catheter remained intact, with the distal end knotted by paramedics. A decision was made to repair the damaged Hickman catheter.
View Article and Find Full Text PDFKorean J Gastroenterol
January 2023
Department of Internal Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea.
The guidewire is an essential accessory in ERCP. Although rare, guidewires can cause complications, such as subcapsular hepatic hematoma, perforation, knotting, fracture, and impaction, during ERCP. This report describes a guidewire impaction during the endoscopic treatment of a patient with symptomatic chronic pancreatitis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!