To compare dosimetric parameters for the hippocampus, organs at risk (OARs), and targets of volumetric modulated arc therapy (VMAT), noncoplanar VMAT (NC-VMAT), and HyperArc (HA) plans in patients undergoing postoperative radiotherapy for primary brain tumors. For 20 patients, HA plans were generated to deliver 40.05 to 60 Gy for the planning target volume (PTV). In addition, doses for the hippocampus and OARs were minimized. The VMAT and NC-VMAT plans were retrospectively generated using the same optimization parameters as those in the HA plans. For the hippocampus, the equivalent dose to be administered in 2 Gy fractions (EQD) was calculated assuming α/β = 2. Dosimetric parameters for the PTV, hippocampus, and OARs in the VMAT, NC-VMAT, and HA plans were compared. For PTV, the HA plans provided significantly lower D and D than the VMAT and NC-VMAT plans (p < 0.05), whereas the D and D were significantly higher (p < 0.05). For the contralateral hippocampus, the dosimetric parameters in the HA plans (8.1 ± 9.6, 6.5 ± 7.2, 5.6 ± 5.8, and 4.8 ± 4.7 Gy for D, D, D and D, respectively) were significantly smaller (p < 0.05) than those in the VMAT and NC-VMAT plans. Except for the optic chiasm, the D in the HA plans (brainstem, lens, optic nerves, and retinas) was the smallest (p < 0.05). In addition, the doses in the HA plans for the brain and skin were the smallest (p < 0.05) among the 3 plans. HA planning, instead of coplanar and noncoplanar VMAT, significantly reduces the dosage to which the contralateral hippocampus as well as other OARs are exposed without compromising on target coverage.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2022.12.001DOI Listing

Publication Analysis

Top Keywords

vmat nc-vmat
20
nc-vmat plans
16
dosimetric parameters
12
plans
12
postoperative radiotherapy
8
radiotherapy primary
8
primary brain
8
brain tumors
8
noncoplanar vmat
8
addition doses
8

Similar Publications

Comparison between Volumetric Modulated arc Therapy based Coplanar and Noncoplanar Planning for Stereotactic Body Radiation Therapy of Liver.

Asian Pac J Cancer Prev

April 2024

Radiotherapy and Oncology, Senior Grade Lecturer, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India.

Article Synopsis
  • The study compares non-coplanar (NC-VMAT) and coplanar (C-VMAT) beam arrangements in liver stereotactic body radiotherapy (SBRT) to assess dosimetric benefits.
  • Thirteen patients' SBRT-VMAT plans were analyzed, showing no significant difference in target volume coverage but lower spine doses and less healthy tissue exposure for NC-VMAT.
  • Overall, NC-VMAT was found to be a superior option due to lower doses delivered to the spine and healthy tissues, along with fewer monitor units used.
View Article and Find Full Text PDF

Dosimetrically motivated beam-angle optimization for non-coplanar arc radiotherapy with and without dynamic collimator rotation.

Med Phys

February 2024

Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland.

Background: Non-coplanar techniques have shown to improve the achievable dose distribution compared to standard coplanar techniques for multiple treatment sites but finding optimal beam directions is challenging. Dynamic collimator trajectory radiotherapy (colli-DTRT) is a new intensity modulated radiotherapy technique that uses non-coplanar partial arcs and dynamic collimator rotation.

Purpose: To solve the beam angle optimization (BAO) problem for colli-DTRT and non-coplanar VMAT (NC-VMAT) by determining the table-angle and the gantry-angle ranges of the partial arcs through iterative 4π fluence map optimization (FMO) and beam direction elimination.

View Article and Find Full Text PDF

Background: Single-isocenter (SI) noncoplanar volumetric modulated arc therapy (NC-VMAT) has been widely used in stereotactic radiosurgery (SRS) or hypofractionated stereotactic radiotherapy (HSRT) for multiple brain metastases (BMs). However, it is critical to verify patient positioning at a noncoplanar couch angle. This study aimed to compare the noncoplanar setup discrepancies between kilo-voltage/mega-voltage image (kV/MV) orthogonal image pairs with a 2-dimensional/3-dimensional (2D/3D) matching mode and noncoplanar cone-beam computed tomography (NC-CBCT) with a 3D/3D matching mode in SI NC-VMAT HSRT for multiple BMs.

View Article and Find Full Text PDF

Aims: To conduct a direct comparison regarding the non-coplanar positioning accuracy between the optical surface imaging system Catalyst HD and non-coplanar cone-beam computed tomography (NC-CBCT) in intracranial single-isocentre non-coplanar stereotactic radiosurgery (SRS) and hypofractionated stereotactic radiotherapy (HSRT).

Materials And Methods: Twenty patients with between one and five brain metastases who underwent single-isocentre non-coplanar volumetric modulated arc therapy (NC-VMAT) SRS or HSRT were enrolled in this study. For each non-zero couch angle, both Catalyst HD and NC-CBCT were used for set-up verification prior to beam delivery.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility of using a simplified non-coplanar volumetric modulated arc therapy (NC-VMAT) and investigate its dosimetric advantages compared with intensity modulated radiation therapy (IMRT) and coplanar volumetric modulated arc therapy (C-VMAT) for hippocampal-avoidance whole brain radiation therapy (HA-WBRT).

Methods: Ten patients with brain metastase (BM) were included for HA-WBRT. Three treatment plans were generated for each case using IMRT, C-VMAT, and NC-VMAT, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!