A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Freezing nitrogen ethanol composite reduces periprosthetic infection caused by Staphylococcus aureus contaminated metal implants: An animal study. | LitMetric

Background: Implant-associated infection remains a major complication of orthopedic surgery. The treatment of such infection is complicated by bacterial biofilm formation on the metal surfaces of implants. Biofilm surrounds and protects the bacteria against the organism's endogenous defense system and from external agents such as antibiotics and mechanical debridement. This study aims to evaluate whether freezing nitrogen ethanol composite (FNEC), the combination of liquid nitrogen and 95% ethanol in a 3 to 1 ratio, used frequently in bone tumor surgery, is capable of disinfecting Staphylococcus aureus contaminated implants.

Methods: The femurs of six New Zealand white rabbits were implanted with S. aureus-contaminated screws, half of which were treated with FNEC before implantation. The femurs were harvested 14 days after implantation. Histological analysis and TUNEL assay were conducted. The autoclaved screw, contaminated screw, and FNEC-treated contaminated screw were investigated using scanning electron microscopy to evaluate the biofilm structure.

Results: The FNEC-treated group had significantly lower relative C-reactive protein levels. An obvious periosteal reaction at the implant site was observed in all rabbits in the non-FNEC group but none was observed in the FNEC-treated group. The FNEC-treated group exhibited fewer empty lacunae, less inflammatory infiltration, and less bone necrosis. Immunohistochemical analysis showed no S. aureus in bone tissue from the FNEC-treated group. Scanning electron microscopy showed disruption of the biofilm on the contaminated screw treated with FNEC.

Conclusion: FNEC showed potential in disinfecting S.aureus-contaminated implants. Further investigation is warranted, such as the effect on the implant-cement-bone interface, for FNEC to be used clinically in treating implant-associated infection.

Download full-text PDF

Source
http://dx.doi.org/10.1097/JCMA.0000000000000853DOI Listing

Publication Analysis

Top Keywords

fnec-treated group
16
contaminated screw
12
freezing nitrogen
8
nitrogen ethanol
8
ethanol composite
8
staphylococcus aureus
8
aureus contaminated
8
implant-associated infection
8
scanning electron
8
electron microscopy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!