By using Flat detector computed tomography (FD-CT), a one-stop-shop approach in the diagnostic workup of acute ischemic stroke (AIS) might be achieved. Although information on upstream vessels is warranted, dedicated FD-CT protocols which include the imaging of the cervical vasculature are still lacking. We aimed to prospectively evaluate the implementation of a new multimodal FD-CT protocol including cervical vessel imaging in AIS patients. In total, 16 patients were included in this study. Eight patients with AIS due to large vessel occlusion (LVO) prospectively received a fully multimodal FD-CT imaging, including non-enhanced flat detector computed tomography (NE-FDCT), dynamic perfusion flat detector computed tomography (FD-CTP) and flat detector computed tomography angiography (FD-CTA) including cervical imaging. For comparison of time metrics and image quality, eight AIS patients, which received multimodal CT imaging, were included retrospectively. Although image quality of NE-FDCT and FD-CTA was rated slightly lower than NE-CT and CTA, all FD-CT datasets were of diagnostic quality. Intracerebral hemorrhage exclusion and LVO detection was reliably possible. Median door-to-image time was comparable for the FD-CT group and the control group (CT:30 min, IQR27-58; FD-CT:44.5 min, IQR31-55, p = 0.491). Door-to-groin-puncture time (CT:79.5 min, IQR65-90; FD-CT:59.5 min, IQR51-67; p = 0.016) and image-to-groin-puncture time (CT:44 min, IQR30-50; FD-CT:14 min, IQR12-18; p < 0.001) were significantly shorter, when patients were directly transferred to the angiosuite, where FD-CT took place. Our study indicates that using a new fully multimodal FD-CT approach including imaging of cervical vessels for first-line imaging in AIS patients is feasible and comparable to multimodal CT imaging with substantial potential to streamline the stroke workflow.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10287862PMC
http://dx.doi.org/10.1007/s10278-022-00699-4DOI Listing

Publication Analysis

Top Keywords

flat detector
20
detector computed
16
computed tomography
16
acute ischemic
8
ischemic stroke
8
multimodal fd-ct
8
including cervical
8
ais patients
8
image quality
8
imaging
6

Similar Publications

Background: K-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons.

View Article and Find Full Text PDF

Application of DynaCT biliary soft tissue reconstruction technology in diagnosis and treatment of hepatolithiasis.

World J Gastrointest Surg

January 2025

Department of Emergency Medicine, Biomedical Innovation Center, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou 510655, Guangdong Province, China.

Background: Hepatobiliary stone disease involves an intrahepatic bile duct stone that occurs above the confluence of the right and left hepatic ducts. One-step percutaneous transhepatic cholangioscopic lithotripsy (PTCSL) using the percutaneous transhepatic one-step biliary fistulation (PTOBF) technique enables the clearing of intrahepatic stones and the resolution of strictures. However, hepatolithiasis with associated strictures still has high residual and recurrence rates after one-step PTCSL.

View Article and Find Full Text PDF

Stacked Scintillators Based Multispectral X-Ray Imaging Featuring Quantum-Cutting Perovskite Scintillators With 570 nm Absorption-Emission Shift.

Adv Mater

January 2025

State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, Zhejiang, 310027, China.

Traditional energy-integration X-ray imaging systems rely on total X-ray intensity for image contrast, ignoring energy-specific information. Recently developed multilayer stacked scintillators have enabled multispectral, large-area flat-panel X-ray imaging (FPXI), enhancing material discrimination capabilities. However, increased layering can lead to mutual excitation, which may affect the accurate discrimination of X-ray energy.

View Article and Find Full Text PDF

Centimeter-Sized CsPbBr Single-Crystal Films for Energy-Resolved Radiation Detection.

ACS Appl Mater Interfaces

January 2025

Beijing Key Laboratory of Construction-Tailorable Advanced Functional Materials and Green Applications Experimental Center of Advanced Materials, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.

Metal halide perovskites (MHPs) are promising materials for radiation detection. Compared with polycrystalline films, single crystals (SCs) have lower defect density, higher carrier mobility, and lifetime. However, the direct synthesis of MHP SCs for large-area flat panel imaging detectors remains challenging.

View Article and Find Full Text PDF

Monolithic U-shaped crystal design for TOF-DOI detectors: a flat top vs. a tapered top.

Biomed Phys Eng Express

January 2025

Advanced Nuclear Medicine Science, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, JAPAN, Chiba, 263-8555, JAPAN.

For brain-dedicated positron emission tomography (PET) scanners, depth-of-interaction (DOI) information is essential to achieve uniform spatial resolution across the field-of-view (FOV) by minimizing parallax error. Time-of-flight (TOF) information can enhance the image quality. In this study, we proposed a novel monolithic U-shaped crystal design that had a tapered geometry to achieve good coincidence timing resolution (CTR) and DOI resolution simultaneously.