Binocular disparity is an important cue to three-dimensional shape. We assessed the contribution of this cue to the reliability and consistency of depth in stereoscopic photographs of natural scenes. Observers viewed photographs of cluttered scenes while adjusting a gauge figure to indicate the apparent three-dimensional orientation of the surfaces of objects. The gauge figure was positioned on the surfaces of objects at multiple points in the scene, and settings were made under monocular and binocular, stereoscopic viewing. Settings were used to create a depth relief map, indicating the apparent three-dimensional structure of the scene. We found that binocular cues increased the magnitude of apparent depth, the reliability of settings across repeated measures, and the consistency of perceived depth across participants. These results show that binocular cues make an important contribution to the precise and accurate perception of depth in natural scenes that contain multiple pictorial cues.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9844501PMC
http://dx.doi.org/10.3390/vision7010001DOI Listing

Publication Analysis

Top Keywords

reliability consistency
8
natural scenes
8
gauge figure
8
apparent three-dimensional
8
surfaces objects
8
binocular cues
8
binocular
5
depth
5
binocular improves
4
improves reliability
4

Similar Publications

Development and validation of the infant nursing assessment scale: Results from exploratory factor analysis and Rasch modeling.

J Pediatr Nurs

January 2025

University of Padua, Laboratory of Studies and Evidence Based Nursing, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, Padua, Italy.

Purpose: The primary challenge in infant care is developing a comprehensive, rapid, and reliable assessment tool that is minimally dependent on subjective evaluations and applicable in various inpatient settings. This study aims to develop and assess the structural validity of the Infant Nursing Assessment Scale (INA), enabling a comprehensive evaluation of hospitalized newborns and infants.

Design And Methods: A development and validation study based on cross-sectional design was undertaken.

View Article and Find Full Text PDF

The aim of this study was to evaluate the clinical benefits and outcomes of adjuvant radiation therapy on adrenocortical carcinoma (ACC) patients. All patients with ACC that were reported between 2010 and 2015 were identified from the Surveillance, Epidemiology, and End Results database. A forward-stepwise Cox proportional hazards regression was used to identify independent risk factors.

View Article and Find Full Text PDF

Background: The absence of a reliable and valid Bangla instrument for measuring somatic symptom disorder hinders research and clinical activities in Bangladesh. The present study aimed at translating and validating the Somatic Symptom Disorder-B criteria (SSD-12).

Method: A cross-sectional design was used with purposively selected clinical (n = 100) and non-clinical (n = 100) samples.

View Article and Find Full Text PDF

The Cystic Fibrosis (CF) Impact Questionnaire (CF-IQ) was qualitatively developed to assess the impact of CF in the context of treatment advancements and increased longevity. This study reports the CF-IQ validation. In this noninterventional validation study, people with CF completed the 40-item CF-IQ and validating patient-reported outcome measures (PROMs) via electronic diaries at enrollment (baseline) and at the 4-week follow-up.

View Article and Find Full Text PDF

The reliability of cardiotocographs as diagnostic tools for fetal well-being is hampered by interpretational variations among healthcare professionals, contributing to high rates of cesarean sections and instrumental deliveries. While adjunct technologies may be used to confirm cases of fetal distress, those in resource constrained areas continue to rely on visual cardiotocograph interpretation to come up with the diagnosis of fetal hypoxia. This study investigated the factors contributing to variations in the visual interpretation of intrapartum cardiotocograph among healthcare professionals in the absence of adjunctive technologies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!