Aim: To compare the clinical efficacy and safety of 2-micron laser and conventional trans-urethral resection of bladder tumor (TURBT) in the treatment of non-muscle-invasive bladder tumor (NMIBT), providing evidence-based evidence for clinical treatment.

Materials And Methods: PubMed, Embase, Cochrane Library, CMB, CNKI, and WanFang databases were searched since their inception until December 2021 for all eligible randomized controlled trials (RCTs) related to 2-micron laser and TURBT for treating NMIBT. Two researchers independently screened the literature, extracted outcome indicators, and assessed the risk of bias according to the inclusion and exclusion criteria. Binary and continuous variables were calculated by relative risk (RR) and mean difference (MD) with 95% confidence interval (95%CI), respectively. RevMan 5.4 and Stata 15.0 software were used for all statistical analysis.

Results: A total of ten RCTs involving 1,163 patients were included: 596 cases in the 2-micron laser group and 567 cases in the TURBT group. The results of the meta-analysis revealed that 2-micron laser has advantages over the TURBT in operative duration (MD = -2.94, 95% confidence interval (CI) [-8.55, 2.68], P = 0.31), operative blood loss (MD = -19.93, 95%CI [-33.26, -6.60], P = 0.003), length of hospital stay (MD = -0.94, 95%CI [-1.38, -0.50], P < 0.001), post-operative bladder irrigation time (MD = -28.60, 95%CI [-50.60, -6.59], P = 0.01), period of catheterization days (MD = -1.07, 95%CI [-1.73, -0.40], P = 0.002), obturator nerve reflex (RR = -0.06, 95%CI [0.02, 0.15], P < 0.001), bladder perforation (RR = 0.14, 95%CI [0.06, 0.35], P < 0.001), and bladder irritation (RR = 0.30, 95%CI [0.20, 0.46], P < 0.001). There was no significant difference between the two surgical methods in post-operative urethral stricture and short-term recurrence of NMIBT.

Conclusion: Compared with TURBT, 2-micron laser may be safer and more effective for NMIBT management. However, these conclusions need to be validated through more high-quality RCTs because of the quality limitations and publication bias of the included studies.

Download full-text PDF

Source
http://dx.doi.org/10.4103/jcrt.jcrt_608_22DOI Listing

Publication Analysis

Top Keywords

2-micron laser
24
bladder tumor
16
efficacy safety
8
safety 2-micron
8
conventional trans-urethral
8
trans-urethral resection
8
resection bladder
8
non-muscle-invasive bladder
8
95% confidence
8
confidence interval
8

Similar Publications

This research explores the application of PAM4 modulation to optical signals in the 2-μm wavelength band for indoor optical communication. Experiments conducted in a simulated atmospheric turbulence environment demonstrated a BER of 10 for the 2-μm laser carrier with PAM4, surpassing the forward error correction threshold. Power loss comparisons to a back-to-back setup showed minimal degradation under various turbulence levels, with losses of 1.

View Article and Find Full Text PDF

Aim: To compare the clinical efficacy and safety of 2-micron laser and conventional trans-urethral resection of bladder tumor (TURBT) in the treatment of non-muscle-invasive bladder tumor (NMIBT), providing evidence-based evidence for clinical treatment.

Materials And Methods: PubMed, Embase, Cochrane Library, CMB, CNKI, and WanFang databases were searched since their inception until December 2021 for all eligible randomized controlled trials (RCTs) related to 2-micron laser and TURBT for treating NMIBT. Two researchers independently screened the literature, extracted outcome indicators, and assessed the risk of bias according to the inclusion and exclusion criteria.

View Article and Find Full Text PDF

We demonstrate high-sensitivity vibrational absorption spectroscopy in the 2-micron wavelength range by using a mode-locked Cr:ZnS laser. Interferometric subtraction and multichannel detection across the broad laser spectrum realize simultaneous background-free detection of multiple vibrational modes over a spectral span of >380 cm. Importantly, we achieve detection of small absorbance on the order of 10, which is well below the detection limit of conventional absorption spectroscopy set by the detector dynamic range.

View Article and Find Full Text PDF

Introduction: The potential of transurethral laser surgery in treating non-muscle invasive bladder cancer (NMIBC) has been confirmed, however which types of lasers may be preferentially prescribed remains a debate. The aim of this network meta-analysis is to investigate the comparative efficacy and safety of transurethral laser surgery with four common types of laser including holmium laser, potassium titanylphosphate (KTP) laser, 2-micron laser or thulium laser for the treatment of NMIBC.

Methods And Analysis: A systematic search will be conducted to search all potentially eligible randomised controlled trials comparing different transurethral laser surgeries with each other or with standard transurethral resection among patients with NMIBC in PubMed, Embase, the Cochrane library, China National Knowledge Infrastructure, Wanfang database and Chongqing VIP from their inception until 31 May 2021.

View Article and Find Full Text PDF

High peak and average power lasers with high wall-plug efficiency, like the Big Aperture Thulium (BAT) laser, have garnered tremendous attention in laser technology. To meet the requirements of the BAT laser, we have developed low-dispersion reflection multilayer dielectric (MLD) gratings suitable for compression of high-energy pulses for operations at 2 micron wavelength. We carried out 10000-on-1 damage tests to investigate the fluence damage thresholds of the designed MLD gratings and mirrors, which were found between 100-230 mJ/cm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!