A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effectiveness of radiation protection systems in the cardiac catheterization laboratory: a comparative study. | LitMetric

Background: As numbers and complexity of percutaneous coronary interventions are constantly increasing, optimal radiation protection is required to ensure operator safety. Suspended radiation protection systems (SRPS) and protective scatter-radiation absorbing drapes (PAD) are novel methods to mitigate fluoroscopic scattered radiation exposure. The aim of the study was to investigate the effectiveness regarding radiation protection of a SRPS and a PAD in comparison with conventional protection.

Methods: A total of 229 cardiac catheterization procedures with SRPS (N = 73), PAD (N = 82) and standard radiation protection (N = 74) were prospectively included. Real-time dosimeter data were collected from the first operator and the assistant. Endpoints were the cumulative operator exposure relative to the dose area product [standardized operator exposure (SOE)] for the first operator and the assistant.

Results: For the first operator, the SRPS and the PAD significantly decreased the overall SOE compared to conventional shielding by 93.9% and 66.4%, respectively (P < 0.001). The protective effect of the SRPS was significantly higher compared to the PAD (P < 0.001). For the assistant, the SRPS and the PAD provided a not statistically significant reduction compared to conventional shielding in the overall SOE by 38.0% and 30.6%, respectively.

Conclusions: The SRPS and the PAD enhance radiation protection significantly compared to conventional protection. In most clinical scenarios, the protective effect of SRPS is significantly higher than the additional protection provided by the PAD. Comparison of the additional radiation protection provided by protective scatter-radiation absorbing drapes (PAD) and the suspended radiation protection system (SRPS) system over standard protection with lead aprons.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10160176PMC
http://dx.doi.org/10.1007/s00392-022-02142-8DOI Listing

Publication Analysis

Top Keywords

radiation protection
20
effectiveness radiation
8
protection systems
8
cardiac catheterization
8
srps pad
8
operator exposure
8
operator
6
protection
5
radiation
5
systems cardiac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!