Background/purpose: Zirconia has recently become a popular material for fixed restorations. The purpose of this study was to use a digital workflow to fabricate monolithic zirconia fixed dental prostheses (FDPs) and assess the connection between variable connector sizes compared to their clinical performance.
Materials And Methods: Clinicians evaluated monolithic zirconia FDPs in 58 patients. After definitive impressions were made, stone casts were obtained. The stone casts were scanned to a standard triangle language (STL) file. A digital wax up was fabricated, and corresponding provisional restorations were milled. Final FDPs were fabricated from a high-translucent zirconia material. During digital fabrication, the connector area of each FDP was recorded while meticulous attention was paid to ensure that the connector cross-sectional area was ≥9 mm for the 3-unit restorations (pontic to retainer) and ≥12 mm for the 4-unit restorations (pontic to pontic). Biological an technical outcomes of the FDPs were performed at 1 week, 6 months and then annually for 6 consecutive years.
Results: A total of 23 men and 35 women received a total of 63 full-contour zirconia FDPs in the posterior regions and were observed for a time period ranging between 50 and 70 months. No decementation occurred and no caries were detected during the observation period, however signs of gingivitis were detected in 4 patients. The dimension of the connector areas was 12 mm in the two broken 4-unit FDPs.
Conclusion: The results of this study suggest that the use of digital scanning and milling to fabricate monolithic zirconia FDPs of posterior regions may be an acceptable alternative restorative approach to traditional metal-ceramic restorations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9831836 | PMC |
http://dx.doi.org/10.1016/j.jds.2022.07.023 | DOI Listing |
Evid Based Dent
January 2025
Eastman Dental Institute, London, UK.
Design: A retrospective cohort study assessing the mid-to-long-term outcomes and risk factors affecting the prosthetic success and survival of implant-supported cross-arch fixed dental prostheses (IFCDPs) with monolithic zirconia frameworks.
Cohort Selection: Forty-seven patients received a total of 51 cross-arch prostheses (27 maxillary and 24 mandibular prostheses), supported by 302 implants. Comprehensive clinical and radiographic records were available over a follow-up period ranging from 5 to 13 years.
Int Dent J
January 2025
Department of Dental Services, Emirates Health Services, Dubai, United Arab Emirates.
Objectives: The aim of this randomised controlled trial was to assess clinical, radiographic and patient reported outcomes of narrow versus standard diameter titanium zirconium (TiZr) implants supporting single crown restorations in posterior sites with limited bone width.
Materials And Methods: Participants requiring replacement of single missing posterior teeth with implant-supported crowns were randomly allocated into 2 treatment groups: narrow (3.3 mm) or standard (4.
Int J Paediatr Dent
January 2025
Pediatric Dentistry Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
Background: The growing demand for esthetic restorative materials highlights the need to evaluate their marginal accuracy and fracture resistance to ensure optimal clinical outcomes for primary molars.
Aim: The aim was to assess the vertical marginal gap distance and fracture resistance of esthetic restorative materials after cyclic loading.
Design: Forty extracted primary molars were randomly divided into four groups: Group I, stainless steel veneered crowns with tooth-colored material; Group II, prefabricated monolithic zirconia crowns; Group III, yttria-partially stabilized zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) crowns; and Group IV, hybrid ceramic CAD/CAM crowns.
Clin Exp Dent Res
February 2025
Department of Prosthodontics, Faculty of Dentistry, Ibb University, Yemen.
Objective: The use of vertical margin design in all-ceramic restoration has generated inquiries regarding its clinical efficacy under diverse dynamic oral conditions. This research aims to assess the marginal fit and fracture resistance of monolithic zirconia crowns featuring vertical margin design as opposed to those with conventional horizontal margin design.
Materials And Methods: Two metal dies were employed to generate replicated resin dies mimicking mandibular first molar preparation.
J Funct Biomater
January 2025
Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8549, Japan.
Highly translucent zirconia (TZ) is frequently used in dentistry. The properties of several highly translucent zirconia materials available in the market require an in-depth understanding. In this study, we assessed the translucency, crystalline phase, mechanical properties, and microstructures of three newly developed highly translucent zirconia materials (Zpex 4.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!