Functional evaluation of optimal index finger proximal interphalangeal joint fusion angle using a simulated joint arthrodesis.

J Biomech

Colegio de Ciencias e Ingenierías "El Politécnico", Universidad San Francisco de Quito USFQ, Quito 17901, Ecuador.

Published: January 2023

This study aims at qualitatively and quantitatively evaluating the effects of simulated index finger proximal interphalangeal (PIP) joint fusion angles on hand kinematic function and performance. Although arthrodesis of the index finger PIP joint is an effective medical procedure that produces a durable, pain-free, and stable joint, it permanently immobilizes the joint. Twenty healthy subjects performed basic functional hand activities with the index finger PIP joint unconstrained (UC) and constrained to selected angles under surveillance of a motion capture system. Our results indicate differences in perceived difficulty, time performance, and the functional ROM of the hand joints when the index finger PIP joint is UC and constrained to 0, 20, and 40 degrees of flexion. The mean total perceived difficulty scores for all 6 tasks were higher for the PIP at 0 degrees than for the UC condition (p < 0.001) and for the PIP at 40 degrees (p = 0.048). The functional ROM presented a smaller total number of hand joints affected by the PIP at 20 degrees (25 in total) than the PIP at 0 (31 in total) and 40 (27 in total) degrees during execution of all 6 tasks tested. Therefore, the decision on the appropriate index finger PIP angle for arthrodesis may be between 20 and 40 degrees, as globally for all 6 tasks tested, 0 degrees exhibited the worst results regarding perceived difficulty, performance time, and number of joints with affected ROM. Selecting the appropriate angle for arthrodesis should consider a more complete set of functional activities.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2023.111442DOI Listing

Publication Analysis

Top Keywords

pip joint
16
finger pip
12
finger proximal
8
proximal interphalangeal
8
joint
8
joint fusion
8
perceived difficulty
8
finger
5
pip
5
functional evaluation
4

Similar Publications

Background: Adhesion formation poses a significant challenge for both patients and hand surgeons following tendon repair. One common strategy to prevent adhesion formation is the use of physical barriers. This study aimed to compare the outcomes of extensor tendon repair with and without the application of the OrthoWrap bioresorbable Sheet, specifically in terms of adhesion prevention.

View Article and Find Full Text PDF

Volar Plate Draping (VPD) for Severely Comminuted Proximal Phalanx Head Fractures.

Indian J Plast Surg

December 2024

The Department of Plastic, Hand and Reconstructive Microsurgery, Ganga Medical Center and Hospitals, Coimbatore, Tamil Nadu, India.

While proximal phalangeal joint injuries with comminution of the base of the middle phalanx are common injuries, proximal interphalangeal (PIP) joint fracture dislocations with an intact base of middle phalanx and a comminuted head of proximal phalanx are rare. Volar plate arthroplasty and other described techniques prevail for the former injury, while the latter does not have any supportive literature on the exact method of management. We herein present a 20-year-old male with a severely comminuted head of proximal phalanx fracture with dislocation of the PIP joint, which was not reconstructable but was managed successfully with a novel technique of volar plate draping that resurfaced the raw phalangeal head.

View Article and Find Full Text PDF

Purpose: Terminal extensor tenotomy or Dolphin tenotomy, is a described treatment for the management of distal interphalangeal (DIP) joint hyperextension in chronic boutonniere deformity. The purpose of this study was to investigate the effects of incremental partial Dolphin tenotomy in correcting boutonniere deformity, with a focus on evaluating the improvement in DIP joint hyperextension deformity and documenting the development of iatrogenic mallet finger.

Methods: Thirty-eight fingers from 10 cadaveric hands were used.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the biomechanical properties of SutureTape as an alternative technique for arthrodesis of the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint arthrodesis when compared with surgical steel wire.

Methods: A total of 32 fingers (index, long, ring, and small) from two matched pair cadaveric hands were used. K-wire and surgical steel wire were used for MCP and PIP joint arthrodesis of the control group (group I), whereas K-wire and SutureTape were used for the experimental group (group II).

View Article and Find Full Text PDF

A 47-year-old female presented with arthritis in the left hand's PIP III. Her symptoms were negative for connective tissue disease or spondyloarthritis, but she had HIV and hepatitis B. Initial tests showed no systemic inflammation or abnormal antibodies, and radiology revealed no bony changes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!