Background: The incidence rate of total joint replacement (TJR) continues to increase due to the aging population and the surgery that is very successful in providing pain relief to and improving function among patients with advanced knee or hip arthritis. Improving patient outcomes and patient satisfaction after TJR remain important goals. Wearable technologies provide a novel way to capture patient function and activity data and supplement clinical measures and patient-reported outcome measures in order to better understand patient outcomes after TJR.
Objective: We examined the current literature to evaluate the potential role of wearable devices and compare them with existing methods for monitoring and improving patient rehabilitation and outcomes following TJR.
Methods: We performed a literature search by using the research databases supported by the University of Massachusetts Chan Medical School's Lamar Soutter Library, including PubMed and Scopus, supplemented with the Google Scholar search engine. A specific search strategy was used to identify articles discussing the use of wearable devices in measuring and affecting postoperative outcomes of patients who have undergone TJR. Selected papers were organized into a spreadsheet and categorized for our qualitative literature review to assess how wearable data correlated with clinical measures and patient-reported outcome measures.
Results: A total of 9 papers were selected. The literature showed the impact of wearable devices on evaluating and improving postoperative functional outcomes. Wearable-collected data could be used to predict postoperative clinical measures, such as range of motion and Timed Up and Go times. When predicting patient-reported outcomes, specifically Hip Disability and Osteoarthritis Outcome Scores/Knee Injury and Osteoarthritis Outcome Scores and Veterans RAND 12-Item Health Survey scores, strong associations were found between changes in sensor-collected data and changes in patient-reported outcomes over time. Further, the step counts of patients who received feedback from a wearable improved over time when compared to those of patients who did not receive feedback.
Conclusions: These findings suggest that wearable technology has the potential to remotely measure and improve postoperative orthopedic patient outcomes. We anticipate that this review will facilitate further investigation into whether wearable devices are viable tools for guiding the clinical management of TJR rehabilitation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9880809 | PMC |
http://dx.doi.org/10.2196/39396 | DOI Listing |
J Cardiothorac Surg
January 2025
Cerrahpasa Medical Faculty, Department of Cardiovascular Surgery, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Objectives: Despite the advances in medicine, aortic dissection remains a cardiac surgery emergency with high mortality and morbidity rates. This study examined the effects of the Glue + Felt technique, which uses biological glue and felt to repair the proximal anastomotic site, on the outcomes of patients with acute type A aortic dissection.
Methods: A total of 108 patients who underwent surgery for acute type A aortic dissection at our clinic between 2007 and 2020 were included in the study.
J Orthop Surg Res
January 2025
Department of Orthopaedic and Trauma Surgery, Medical Faculty, University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
Background: Osteoporosis, a skeletal disorder affecting nearly 20% of the global population, poses a significant health concern, with osteoporotic vertebral body fractures (VBF) representing a common clinical manifestation. The impact of osteoporotic sintering fractures in the thoracolumbar spine on the sagittal lumbar profile is incompletely understood and may lead to the onset of clinical symptoms in previously asymptomatic patients.
Methods: This retrospective single-center study analyzed data from patients presenting with osteoporotic spine fractures between 2017 and 2022.
J Cardiothorac Surg
January 2025
Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China.
Background: Near-infrared spectroscopy (NIRS) enables a non-invasive measurement of tissue oxygen saturation (StO) in regions illuminated by near-infrared lights. Vascular occlusion test (VOT) serves as a model to artificially induce forearm ischemia-reperfusion. The combination of StO monitoring and VOT allows for dynamic evaluation of the balance between oxygen delivery and consumption in tissue, as well as the functional reserve of microcirculation.
View Article and Find Full Text PDFTrials
January 2025
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-Ro 43-Gil, Songpa-Gu, Seoul, 05505, Korea.
Background: Prophylactic parenteral administration of antibiotics is strongly recommended to prevent surgical site infection (SSI). Cefoxitin is mainly administered intravenously in colorectal surgery. The current standard method for administering prophylactic antibiotics in adults is to administer a fixed dose quickly before skin incision.
View Article and Find Full Text PDFImmun Ageing
January 2025
State Key Laboratory of Genetic Evolution & Animal Models, Key Laboratory of Bioactive Peptides of Yunnan Province, KIZ-CUHK Joint Laboratory of Bioresources and Molecular Research in Common Diseases, Kunming Institute of Zoology, Chinese Academy of Sciences, Kunming, 650223, Yunnan, China.
Background: Older people living with HIV-1 (PLWH) experience a dual burden from the combined effects of aging and HIV-1 infection, resulting in significant immune dysfunction. Despite receiving HAART, immune reconstitution is not fully optimized. The objective of this study was to investigate the impact of aging and HAART on T cell subsets and function in PLWH across different age groups, thereby providing novel insights into the prognosis of older PLWH.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!