A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Universal and rapid detection of atrazine and bisphenol A using a reusable optical fiber chemiluminescent biosensor. | LitMetric

Timely and accurately detection of small molecule pollutants is quite necessary to control environmental pollution and reduce harmfulness. Herein, a reusable optical fiber chemiluminescent biosensor (ROFC) was proposed for universal and rapid detection of two representative pollutants, pesticide atrazine (ATZ) and endocrine disruptor bisphenol A (BPA). The optical fiber modified with hapten-protein conjugates was regarded as both bio-probe and chemiluminescence signal transmission element, which effectively improved the light transmission efficiency and signal-to-noise ratio of the system. High-sensitive chemiluminescence signal detection is realized with a miniaturized ultrasensitive photodiode detector. Good regeneration performance of bio-probe can reduce detection cost and ensure detection reproducibility. Based on indirect competitive immunoassay principle, the chemiluminescence signal decreased with increasing pollutant concentration resulting from the less amount of antibody combined on the bio-probe surface. Under optimal conditions, the whole assay was achieved within 25 min with linear range of 1-100 μg/L and detection limits (LOD) for atrazine and BPA are 0.029 μg/L and 0.025 μg/L, respectively. The immunosensing optical fiber probe can be reused for 150 times at least without losing obvious bioactivity. The method was successfully applied to the detection of ATZ and BPA in three environmental samples, where recoveries between 93.4% and 116.6% were achieved. The ROFC biosensor provides a feasible platform for rapid detection of multiple small molecule pollutants in the environment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2023.124252DOI Listing

Publication Analysis

Top Keywords

optical fiber
16
rapid detection
12
chemiluminescence signal
12
detection
9
universal rapid
8
reusable optical
8
fiber chemiluminescent
8
chemiluminescent biosensor
8
small molecule
8
molecule pollutants
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!