A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Combining thermal imaging and spectral pyrometry for express temperature mapping in additive manufacturing. | LitMetric

A compact and low-cost two-dimensional (2D) thermal imager was developed for real-time temperature mapping of a melt pool during coaxial laser cladding (the additive manufacturing technique). The device combines a color CMOS camera and a compact spectrometer. The spectrometer was utilized for internal calibration and validation of a 2D temperature map that was acquired by the CMOS camera. The remarkable feature of the thermal imager is that camera images are calibrated directly during the measurement process utilizing spectral pyrometry. Additionally, the spectrometer decreased a potential systematic error due to a spectrum contribution from atomic/ionic lines emission. The spectral pyrometry provided temperature accuracy measurements of ±23 while two-dimensional (2D) temperature mapping by two-color pyrometry accuracy was estimated as ±38 in the range of 1700-3500 K. The system has been installed at a coaxial laser cladding head for real-time temperature mapping. The system was developed for measuring a melt pool during laser cladding production of a high wear-resistant coating (tungsten carbide particles in a nickel matrix). Tungsten carbides powder flow rate has been changed sequentially from 5 to 27 g/min by powder feeder programming, which resulted in a variation of melt pool dimensions and temperature maps during the cladding process.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.478113DOI Listing

Publication Analysis

Top Keywords

temperature mapping
16
spectral pyrometry
12
melt pool
12
laser cladding
12
additive manufacturing
8
thermal imager
8
real-time temperature
8
coaxial laser
8
cmos camera
8
temperature
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!