Swept-source optical coherence tomography and ultrasound biomicroscopy study of anterior segment parameters in primary angle-closure glaucoma.

Graefes Arch Clin Exp Ophthalmol

State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Eye Institute of Shandong First Medical University, 5 Yanerdao Road, Qingdao, Shandong Province, 266071, China.

Published: June 2023

Purpose: To evaluate the agreement between swept-source OCT (CASIA2) and UBM in primary angle-closure glaucoma.

Methods: Eighty eyes of 40 participants diagnosed with primary angle-closure glaucoma were examined. Parameters measured included angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), trabecular iris angle (TIA), lens vault (LV), anterior chamber depth (ACD), and anterior chamber width (ACW). Angle images of nasal, temporal, superior, and inferior were acquired by the anterior segment mode of CASIA2 and UBM. One-way analysis of variance and paired t-test were used for statistical analysis, and the agreement was analyzed by internal correlation coefficient (ICC) and Bland-Altman method.

Results: One-way ANOVA pairwise comparison showed that CASIA2 or UBM had the narrowest superior chamber angle and the widest temporal chamber angle in patients with primary angle-closure glaucoma. The paired t-test showed that inter-device AOD, TIA, ARA, and TISA of superior chamber angle had significant differences (p < 0.001). There was no significant difference in the measured values of LV, ACD, and ACW (p > 0.05). The agreement of all parameters is good through the Bland-Altman method comparison. ICC result showed moderate agreement in other angle parameters except for superior ARA500 (0.739).

Conclusion: In the anterior chamber angle measurement process, we should pay more attention to the superior chamber angle covered by eyelids. Although the agreement is acceptable between CASIA2 and UBM, the measurements could not be considered interchangeable due to the tremendous statistical difference between the two devices.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-022-05970-6DOI Listing

Publication Analysis

Top Keywords

chamber angle
20
primary angle-closure
16
casia2 ubm
16
angle-closure glaucoma
12
anterior chamber
12
superior chamber
12
angle
10
anterior segment
8
trabecular iris
8
paired t-test
8

Similar Publications

Lipid nanoparticle-mediated intracameral mRNA delivery facilitates gene expression and editing in the anterior chamber of the eye.

J Control Release

January 2025

Department of Pharmaceutical Sciences, College of Pharmacy, Robertson Life Sciences Building, Oregon State University, Portland, OR 97201, USA; Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR 97239, USA; Department of Biomedical Engineering, Robertson Life Sciences Building, Oregon Health & Science University, Portland, OR 97201, USA. Electronic address:

Lipid nanoparticles (LNPs) have shown great potential in the field of gene therapy for retinal diseases. To expand on this application, we investigated LNP-mediated mRNA delivery to the anterior chamber of the eye via the intracameral (IC) route of administration. Here, we show that IC injections of LNPs facilitated protein expression and gene editing in the trabecular meshwork (TM).

View Article and Find Full Text PDF

We present a case of Acute Angle-Closure Crisis (AACC) precipitated by primary transient psychogenic polydipsia; we believe that our case is the first of its kind to be reported. A 74-year-old male presented to the emergency department with altered mental status due to acute-onset hyponatremia. Six days after admission, the patient noticed painful loss of vision in his right eye and an ipsilateral headache lasting 10-15 minutes.

View Article and Find Full Text PDF

Differences in Ocular Biometry Between Short-Axial and Normal-Axial Eyes in the Elderly Japanese.

Clin Ophthalmol

January 2025

Department of Ophthalmology, Saitama Medical Center, Saitama Medical University, Kawagoe-shi, Saitama, Japan.

Purpose: Among patients with angle-closure glaucoma, it is common to have a short-axial eye, which also makes it difficult to select an appropriate intraocular lens. Previous studies have focused on the ocular biometry of the long-axial eye, whereas only a few reports have focused on the short-axial eye. This study aimed to clarify the characteristics of the short-axial eye on ocular biometry among the elderly Japanese.

View Article and Find Full Text PDF

Can fundus features tell us something about 3D eye shape?

Ophthalmic Physiol Opt

January 2025

Robert O Curle Ophthalmology Suite, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, UK.

Purpose: To determine whether imaging features derived from fundus photographs contain 3D eye shape information beyond that available from spherical equivalent refraction (SER).

Methods: We analysed 99 eyes of 68 normal adults in the UK Biobank. An ellipsoid was fitted to the entire volume of each posterior eye (vitreous chamber without the lens)-segmented from magnetic resonance imaging of the brain.

View Article and Find Full Text PDF

Purpose: To characterize the anterior segment (AS) morphology of patients with long-term silicone oil (SiO) in situ (> 12 months) following pars plana vitrectomy (PPV).

Methods: This prospective, comparative characterization study was conducted between January 2022 and July 2023. Patients were included and sorted based on if they had undergone PPV without long-term SiO or had SiO in situ for at least 12 months at the time of review and image collection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!