Aims: This study aims to determine the inactivation kinetics of Geobacillus stearothermophilus and Bacillus atrophaeus biological indicators, treated with vaporized hydrogen peroxide (VH2O2) at an industrial scale. There is an assumption that sterilization processes generate linear kinetic plots of treated biological indicators that are used for informing probability-based decision-making by the MedTech industry for effective sterilization treatments; however, this has not been reported for sterilization using VH2O2.

Methods And Results: Survivor curves were generated, and sterilization performances were separately determined using G. stearothermophilus and B. atrophaeus biological indicators following the development of appropriate process challenge devices (PCDs). Regression analysis revealed that the inactivation kinetics for VH2O2-treated microorganisms exhibited log linear profiles. The use of scanning electron microscope (SEM) revealed no significant topographical changes in the outer surface of these VH2O2-treated spores.

Conclusions: Both biological indicators exhibited log linear inactivation kinetics when treated with an industrial scale vaporized hydrogen peroxide (VH2O2) sterilization process. Therefore, this novel finding corroborates and proves the appropriateness of using VH2O2 as a sterilization method in accordance with applicable ISO standards.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jambio/lxac028DOI Listing

Publication Analysis

Top Keywords

biological indicators
16
industrial scale
12
vaporized hydrogen
12
hydrogen peroxide
12
peroxide vh2o2
12
vh2o2 sterilization
12
inactivation kinetics
12
geobacillus stearothermophilus
8
stearothermophilus bacillus
8
bacillus atrophaeus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!