Background: Robotic ophthalmic endoscope holders allow surgeons to execute dual-hand operations in eye surgery. To prevent needle-like endoscopes from invading the retina when moving, surgeons expect visual and real-time information about the relative special relationship between the endoscope and fundus.

Methods: This study develops a real-time fundus reconstruction method. First, using deep learning, the method estimates the distance between the fundus part corresponding to every pixel of the RGB endoscopic image and the endoscope. Then, by combining the estimated distance with the kinematics of a robotic holder, the point cloud representing the present fundus area is generated, and by which the size and position of the eyeball are estimated.

Results: This method shows a real-time frequency of 10 Hz, which is robust to eyeball movement. The error of fundus reconstruction is about 0.5 mm, and the error of eyeball estimation is about 1 mm.

Conclusion: Using this fundus reconstruction method can map the position of the endoscope inside the eyeball when using a robotic endoscope holder in eye surgery. The overall accuracy level meets the ophthalmologists' accuracy requirements of ophthalmologists.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcs.2496DOI Listing

Publication Analysis

Top Keywords

fundus reconstruction
16
real-time fundus
8
ophthalmic endoscope
8
eye surgery
8
reconstruction method
8
endoscope
6
fundus
5
real-time
4
reconstruction
4
reconstruction intraocular
4

Similar Publications

Background And Objective: Accurate extraction of retinal vascular components is vital in diagnosing and treating retinal diseases. Achieving precise segmentation of retinal blood vessels is challenging due to their complex structure and overlapping vessels with other anatomical features. Existing deep neural networks often suffer from false positives at vessel branches or missing fragile vessel patterns.

View Article and Find Full Text PDF

Background And Objective: Cerebral aneurysms occur as balloon-like outpouchings in an artery, which commonly develop at the weak curved regions and bifurcations. When aneurysms are detected, understanding the risk of rupture is of immense clinical value for better patient management. Towards this, Fluid-Structure Interaction (FSI) studies can improve our understanding of the mechanics behind aneurysm initiation, progression, and rupture.

View Article and Find Full Text PDF

Outcomes after revisional surgery for paraesophageal hernias at a high-volume tertiary care center.

Surg Endosc

December 2024

Division of Thoracic and Upper Gastrointestinal Surgery, Department of Surgery, McGill University Health Centre, L8 505-1650 Cedar Ave, Montreal, QC, H3G 1A4, Canada.

Article Synopsis
  • Repairing recurrent giant paraesophageal hernias (PEH) has a higher complication rate than initial surgeries, which leads to hesitation in performing these procedures unless patients are symptomatic.
  • A study analyzed outcomes of revisional PEH repairs compared to primary repairs, focusing on patient demographics and recovery times between 2012 and 2019.
  • The research found that while revisional surgeries faced more complications, longer recovery times, and a higher conversion rate to open surgery, the incidence of severe complications was similar to those undergoing primary repairs.
View Article and Find Full Text PDF

To compare the short-term efficacy of laparoscopic sleeve gastrectomy (LSG) combined with sharp His angle reconstruction (LSG-His) versus traditional LSG. In this retrospective cohort study we collected clinical data of patients with obesity who had undergone LSG or LSG-His in the Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, from January to June 2022. After excluding patients with incomplete follow-up data and those with hiatal hernia, 83 obese patients, of which 39 who had undergone LSG (LSG group) and 44 who had undergone LSG-His (LSG-His group), were included in the study.

View Article and Find Full Text PDF

Various ocular diseases such as cataracts, glaucoma, and diabetic retinopathy have become several major factors causing non-congenital visual impairment, which seriously threatens people's vision health. The shortage of ophthalmic medical resources has brought huge obstacles to large-scale ocular disease screening. Therefore, it is necessary to use computer-aided diagnosis (CAD) technology to achieve large-scale screening and diagnosis of ocular diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!