Introduction: In the randomized PARTNER 3 trial, transcatheter aortic valve implantation (TAVI) with the SAPIEN 3 device significantly reduced a composite of all-cause death, stroke, and rehospitalization, compared with surgical aortic valve replacement (SAVR), in patients with severe symptomatic aortic stenosis and low risk of surgical mortality. Furthermore, TAVI has been shown to be cost-effective in low-risk patients, compared with SAVR, in a number of countries. This study aimed to determine the cost-effectiveness of TAVI with SAPIEN 3 versus SAVR in Germany.
Methods: A previously published two-stage Markov-based model that captured clinical outcomes from the PARTNER 3 trial was adapted for the German context using the German Statutory Health Insurance perspective. The model had a lifetime horizon. The cost-utility analysis estimated changes in direct healthcare costs as well as survival and health-related quality of life using TAVI with SAPIEN 3 compared with SAVR.
Results: TAVI with SAPIEN 3 increased quality-adjusted life years (QALYs) by + 0.72 at an increased cost of €8664 per patient. The incremental cost-effectiveness/QALY ratio was €12,037, which fell below that of other cardiovascular interventions in use in Germany. The cost-effectiveness of TAVI over SAVR remained robust across multiple challenging scenarios and was driven by lower longer-term management costs compared with SAVR.
Conclusions: TAVI with SAPIEN 3 appears to be a clinically meaningful, cost-effective treatment option over SAVR for patients with severe symptomatic aortic stenosis and low risk for surgical mortality in Germany.
Clinical Trial Registration Number: www.
Clinicaltrials: gov identifier: NCT02675114.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9988804 | PMC |
http://dx.doi.org/10.1007/s12325-022-02392-y | DOI Listing |
Int J Cardiol Heart Vasc
February 2025
Department of Medicine, Lady Davis Carmel Medical Center, Haifa, Israel.
Background: Aortic stenosis (AS) is treated through transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR), with diabetes being prevalent among these patients. Inflammation participates in the pathogenesis of AS, and emerging evidence suggests that TAVI may exert anti-inflammatory effects. Given the established link between diabetes and inflammation, we sought to evaluate the impact of aortic valve replacement (AVR) on glycemic control.
View Article and Find Full Text PDFHellenic J Cardiol
January 2025
Department of Cardiology, University Hospital of Split, 21000 Split, Croatia. Electronic address:
Background: Anatomic considerations of transcatheter aortic valve implantation (TAVI) have an important role for the procedure planning, but sex-specific data are lacking.
Methods: All eligible cases undergoing evaluation for TAVI procedure in the period from November 2019 to July 2023 at the University Hospital of Split were included. Cardiac computed tomography was analysed to derive the measures of left ventricular outflow tract (LVOT), aortic root, ascending aorta, and ilio-femoral arteries.
Radiol Case Rep
March 2025
Department of Medical Imaging, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Jeddah, Saudi Arabia.
Subclavian artery pseudoaneurysm (SAP) is a rare but lethal diagnosis, and an important condition that should be detected and managed imperatively. SAP has been seldom described in the literature, explaining the lack of concrete management guidelines. Herein we present a case study of a 63-year-old man with SAP post a transcatheter aortic valve implantation (TAVI) done 8 days prior to current presentation.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Hackensack University Medical Center, Hackensack, New Jersey, USA.
Background: Patients with prior history of chest or mediastinal radiation are deemed high risk for surgical AVR. Transcatheter aortic valve replacement (TAVR) has emerged as a promising alternative for these patients, however, this patient population was underrepresented in prior TAVR trials.
Aims: To compare the outcomes of TAVR in patients with versus without a history of prior chest or mediastinal radiation.
Arch Cardiovasc Dis
December 2024
Nantes Université, CHU Nantes, Unité Hémodynamique et Cardiologie Interventionnelle, l'institut du thorax, 44000 Nantes, France.
Background: Few studies have assessed coronary physiology in the setting of coronary artery disease (CAD) with severe aortic stenosis (AS). Fractional flow reserve (FFR) to guide revascularization in such patients is not validated.
Aims: We describe changes in coronary physiology in this population before and after transcatheter aortic valve implantation (TAVI).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!