Convenient tools to assess canine skeletal muscle health would be useful for a variety of applications, including standard veterinary assessments of dog fitness, as well as studies of muscle deterioration due to age or disease. One technology that can be applied conveniently to awake dogs with minimal restraint is electrical impedance myography (EIM). In EIM, a weak electrical current is applied surface electrodes to a muscle of interest and consequent impedance characteristics of the muscle are obtained, providing insight into muscle condition and composition. In this study, we assessed a total of 73 dogs (42 males and 31 females), of varied neutering status and breed, ages 0.6 to 13.5 years. We identified age-dependent reference values for the 100 kHz phase value in three pelvic limb muscles, caudal sartorius, cranial tibial, and gastrocnemius. While phase values were generally higher in males than females, the difference did not reach significance. In general, values declined on average with age at about 0.5 degrees/year, but with the decline being most substantial in the oldest dogs. Limited reproducibility assessment of the technique suggested good repeatability with variation in values between measurements being under 5%. These results show that EIM has the potential for the assessment of canine muscle health and may find value in aging muscle research.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9811316 | PMC |
http://dx.doi.org/10.3389/fvets.2022.1025528 | DOI Listing |
Sci Rep
December 2024
Department of Theoretical Electrical Engineering and Diagnostics of Electrical Equipment, Institute of Electrodynamics, National Academy of Sciences of Ukraine, Beresteyskiy, 56, Kyiv-57, Kyiv, 03680, Ukraine.
In this paper, an improved voltage control strategy for microgrids (MG) is proposed, using an artificial neural network (ANN)-based adaptive proportional-integral (PI) controller combined with droop control and virtual impedance techniques (VIT). The control strategy is developed to improve voltage control, power sharing and total harmonic distortion (THD) reduction in the MG systems with renewable and distributed generation (DG) sources. The VIT is used to decouple active and reactive power, reduce negative power interactions between DG's and improve the robustness of the system under varying load and generation conditions.
View Article and Find Full Text PDFBiosensors (Basel)
December 2024
Department of Electrical-Electronics Engineering, Abdullah Gul University, Kayseri 38039, Türkiye.
detection suffers from slow analysis time and high costs, along with the need for specificity. While state-of-the-art electrochemical biosensors are cost-efficient and easy to implement, their sensitivity and analysis time still require improvement. In this work, we present a paper-based electrochemical biosensor utilizing magnetic core-shell FeO@CdSe/ZnS quantum dots (MQDs) to achieve fast detection, low cost, and high sensitivity.
View Article and Find Full Text PDFBiosensors (Basel)
November 2024
Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, USA.
Hepatitis A virus (HAV), a major cause of acute liver infections, is transmitted through the fecal-oral route and close contact with infected individuals. Current HAV standardized methods rely on the detection of virus antigen or RNA, which do not differentiate between infectious and non-infectious HAV. The objective of this study was to develop a prototype cell-based electrochemical biosensor for detection of infectious HAV.
View Article and Find Full Text PDFFront Bioeng Biotechnol
December 2024
Electrical and Computer Engineering Department, Lebanese American University, Byblos, Lebanon.
This scoping review summarizes two emerging electrical impedance technologies: electrical impedance myography (EIM) and electrical impedance tomography (EIT). These methods involve injecting a current into tissue and recording the response at different frequencies to understand tissue properties. The review discusses basic methods and trends, particularly the use of electrodes: EIM uses electrodes for either injection or recording, while EIT uses them for both.
View Article and Find Full Text PDFEnergy Environ Sci
December 2024
Department of Physics, University of Oxford, Clarendon Laboratory Oxford OX1 3PU UK
It is widely accepted that mobile ions are responsible for the slow electronic responses observed in metal halide perovskite-based optoelectronic devices, and strongly influence long-term operational stability. Electrical characterisation methods mostly observe complex indirect effects of ions on bulk/interface recombination, struggle to quantify the ion density and mobility, and are typically not able to fully quantify the influence of the ions upon the bulk and interfacial electric fields. We analyse the bias-assisted charge extraction (BACE) method for the case of a screened bulk electric field, and introduce a new characterisation method based on BACE, termed ion drift BACE.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!