Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studied in the lab on a 10-m-long defective MVAC cable. The three PCB-based sensors were tested in three different positions: directly on the defective cable (P1), at a separation distance of 10 cm to 3 m (P2), and on the ground line (P3). For the three positions, all sensors' outputs present a damped sine wave signal with similar frequencies and durations. Experimental results showed that the best sensitivity was given by the non-spiral inductor, with a peak voltage of around 500 mV in P1, 428 mV in P2, and 45 mV in P3, while the meander sensor had the lowest values, which were approximately 80 mV in P1. The frequency spectrum bandwidth of all sensors was between 10 MHz and 45 MHz. The high sensitivity of the non-spiral inductor could be associated with its interesting properties in terms of quality factor and SFR, which are due to its very low resistivity. To benchmark the performance of the designed three-loop sensors, a comparison with a commercial high-frequency current transformer (HFCT) is also made.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824703 | PMC |
http://dx.doi.org/10.3390/s23010290 | DOI Listing |
Sensors (Basel)
January 2025
Hubei Key Laboratory of Power Equipment & System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.
High-voltage (HV) cables are increasingly used in urban power grids, and their safe operation is critical to grid stability. Previous studies have analyzed various defects, including the open circuit in the sheath loop, the flooding in the cross-bonded link box, and the sheath grounding fault. However, there is a paucity of research on the defect of the reverse direction between the inner core and the outer shield of the coaxial cable.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China.
Accurately measuring the thickness of the oxide film that accumulates on nuclear fuel assemblies is critical for maintaining nuclear power plant safety. Oxide film thickness typically ranges from a few micrometers to several tens of micrometers, necessitating a high-precision measurement system. Eddy current testing (ECT) is commonly employed during poolside inspections due to its simplicity and ease of on-site implementation.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
School of Civil & Environmental Engineering and Geography Science, Ningbo University, Ningbo 315211, China.
To improve the application of carbon-fiber-reinforced polymers (CFRPs) in civil engineering, the long-term durability of CFRP anchorage systems has become a critical issue. Temperature fluctuations can significantly impact the bond performance between CFRPs and the load transfer medium (LTM), making it essential to understand the effects of temperature on the durability of CFRP anchorages. Therefore, this study investigates the influence of temperature on the durability of CFRP anchorages through aging tests on 30 epoxy-filled CFRP-bonded anchorage specimens, followed by pull-out tests.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China.
Embedding stacked HTS tapes into twisted slots is one design approach for constructing fusion conductors. This paper adopts a Cable-in-Conduit Conductor (CICC) structure, utilizing commercially REBCO coated conductors. The cable framework is made of copper and features six helically twisted slots filled with 2G HTS tapes.
View Article and Find Full Text PDFBioinspir Biomim
January 2025
Chinese Academy of Agricultural Sciences, Chengdu 610213, PR China, Beijing, 100081, CHINA.
Among the components of a humanoid robot, a humanoid torso plays a vital role in supporting a humanoid robot to complete the desired motions. In this paper, a new LARMbot torso is developed for obtaining better working performance based on biological features. Through analyzing the anatomy of a human torso and human spine, a parallel cable-driven is proposed to actuate the whole mechanism by using two servo motors and two pulleys.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!