AI Article Synopsis

  • ECoG (electrocorticogram) technology captures electrical activities from the brain, showing great potential for future brain-computer interface applications.
  • Significant advancements in creating soft, biocompatible materials for brain devices have been made, but challenges remain in optimizing these materials' electrical and mechanical properties.
  • The new STICH hydrogel, with its unique softness and toughness, has shown promising results in experimental settings, improving electrode performance and enhancing the quality of electrical recordings from brain activity in tests conducted on rodents.

Article Abstract

An electrocorticogram (ECoG) is the electrical activity obtainable from the cerebral cortex and an informative source with considerable potential for future advanced applications in various brain-interfacing technologies. Considerable effort has been devoted to developing biocompatible, conformal, soft, and conductive interfacial materials for bridging devices and brain tissue; however, the implementation of brain-adaptive materials with optimized electrical and mechanical characteristics remains challenging. Herein, we present surface electrode arrays using the soft tough ionic conductive hydrogel (STICH). The newly proposed STICH features brain-adaptive softness with Young's modulus of ~9.46 kPa, which is sufficient to form a conformal interface with the cortex. Additionally, the STICH has high toughness of ~36.85 kJ/mm, highlighting its robustness for maintaining the solid structure during interfacing with wet brain tissue. The stretchable metal electrodes with a wavy pattern printed on the elastomer were coated with the STICH as an interfacial layer, resulting in an improvement of the impedance from 60 kΩ to 10 kΩ at 1 kHz after coating. Acute in vivo experiments for ECoG monitoring were performed in anesthetized rodents, thereby successfully realizing conformal interfacing to the animal's cortex and the sensitive recording of electrical activity using the STICH-coated electrodes, which exhibited a higher visual-evoked potential (VEP) amplitude than that of the control device.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9824691PMC
http://dx.doi.org/10.3390/polym15010084DOI Listing

Publication Analysis

Top Keywords

surface electrode
8
electrode arrays
8
conductive hydrogel
8
electrical activity
8
brain tissue
8
stretchable surface
4
arrays alginate/pedotpss-based
4
alginate/pedotpss-based conductive
4
conformal
4
hydrogel conformal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!