It is known that visual feedback by fluoroscopy can detect electrode array (EA) misrouting within the cochlea while robotized EA-insertion (rob-EAI) permits atraumatic cochlear implantation. We report here our unique experience of both fluoroscopy feedback and rob-EAI in cochlear implant surgery. We retrospectively analyzed a cohort of consecutive patients implanted from November 2021−October 2022 using rob-EAI, with the RobOtol®, to determine the quality of EA-insertion and the additional time required. Twenty-three patients (10 females, 61+/−19 yo) were tentatively implanted using robot assistance, with a rob-EAI speed < 1 mm/s. Only three cases required a successful revised insertion by hand. Under fluoroscopy (n = 11), it was possible to achieve a remote rob-EAI (n = 8), as the surgeon was outside the operative room, behind an anti-radiation screen. No scala translocation occurred. The additional operative time due to robot use was 18+/−7 min with about 4 min more for remote rob-EAI. Basal cochlear turn fibrosis precluded rob-EAI. In conclusion, Rob-EAI can be performed in almost all cases with a low risk of scala translocation, except in the case of partial cochlear obstruction such as fibrosis. Fluoroscopy also permits remote rob-EAI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9820833PMC
http://dx.doi.org/10.3390/jcm12010211DOI Listing

Publication Analysis

Top Keywords

remote rob-eai
12
rob-eai
9
cochlear implantation
8
scala translocation
8
fluoroscopy
5
robotized cochlear
4
implantation fluoroscopy
4
fluoroscopy preliminary
4
preliminary series
4
series visual
4

Similar Publications

Robotized Cochlear Implantation under Fluoroscopy: A Preliminary Series.

J Clin Med

December 2022

Department of Radiology, University Hospital Center, Hospital Gabriel Montpied, 58, Rue Montalembert, 63000 Clermont-Ferrand, France.

It is known that visual feedback by fluoroscopy can detect electrode array (EA) misrouting within the cochlea while robotized EA-insertion (rob-EAI) permits atraumatic cochlear implantation. We report here our unique experience of both fluoroscopy feedback and rob-EAI in cochlear implant surgery. We retrospectively analyzed a cohort of consecutive patients implanted from November 2021−October 2022 using rob-EAI, with the RobOtol®, to determine the quality of EA-insertion and the additional time required.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!