Monochromatic computed tomography using laboratory-scale setup.

Sci Rep

Department of Physics, University of Helsinki, P.O. Box 64, 00014, Helsinki, Finland.

Published: January 2023

In this article, we demonstrate the viability of highly monochromatic full-field X-ray absorption near edge structure based tomography using a laboratory-scale Johann-type X-ray absorption spectrometer utilising a conventional X-ray tube source. In this proof-of-concept, by using a phantom embedded with elemental Se, Na[Formula: see text]SeO[Formula: see text], and Na[Formula: see text]SeO[Formula: see text], we show that the three-dimensional distributions of Se in different oxidation states can be mapped and distinguished from the phantom matrix and each other with absorption edge contrast tomography. The presented method allows for volumetric analyses of chemical speciation in mm-scale samples using low-brilliance X-ray sources, and represents a new analytic tool for materials engineering and research in many fields including biology and chemistry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9825405PMC
http://dx.doi.org/10.1038/s41598-023-27409-6DOI Listing

Publication Analysis

Top Keywords

tomography laboratory-scale
8
x-ray absorption
8
absorption edge
8
na[formula text]seo[formula
8
text]seo[formula text]
8
monochromatic computed
4
computed tomography
4
laboratory-scale setup
4
setup article
4
article demonstrate
4

Similar Publications

Evaluation of the Wear of Ni 200 Alloy After Long-Term Carbon Capture in Molten Salts Process.

Materials (Basel)

December 2024

Department of Geomechanics, Civil Engineering and Geotechnics, Faculty of Civil Engineering and Resource Management, AGH University of Krakow, al. Adama Mickiewicza 30, 30-059 Cracow, Poland.

Reducing CO emissions is one of the major challenges facing the modern world. The overall goal is to limit global warming and prevent catastrophic climate change. One of the many methods for reducing carbon dioxide emissions involves capturing, utilizing, and storing it at the source.

View Article and Find Full Text PDF

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools.

View Article and Find Full Text PDF

Optically Transparent Lead Halide Perovskite Polycrystalline Ceramics.

ACS Appl Mater Interfaces

March 2024

Air Force Research Laboratory, Materials and Manufacturing Directorate, Wright-Patterson Air Force Base, Ohio 45433, United States.

We utilize room-temperature uniaxial pressing at applied loads achievable with low-cost, laboratory-scale presses to fabricate freestanding CHNHPbX (X = Br, Cl) polycrystalline ceramics with millimeter thicknesses and optical transparency up to ∼70% in the infrared. As-fabricated perovskite ceramics can be produced with desirable form factors (i.e.

View Article and Find Full Text PDF

Recently, a novel radiohybrid tracer [F]Lu-LuFL targeting the fibroblast activation protein (FAP) has been developed for PET imaging of solid tumors. This tracer has shown promising results, prompting us to conduct a first-in-human study to evaluate its efficacy for PET imaging of FAP in human body. In order to facilitate the routine production and clinical application of [F]Lu-LuFL, a straightforward and efficient automated synthesis is described.

View Article and Find Full Text PDF

On the Structural, Thermal, Micromechanical and Tribological Characterizations of Cu-Filled Acrylonitrile Butadiene Styrene Micro-Composites.

Materials (Basel)

September 2023

Department of Mechanical Engineering, Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal.

The purpose of this work was to investigate the structural, thermal, micromechanical and tribological properties of novel polymer/metal composite materials for bearing applications. Copper (Cu)-filled Acrylonitrile Butadiene Styrene (ABS) composites were mixed in a laboratory scale by an internal mixer with two blade impellers, and then injection-molded. Neat ABS, ABS+5wt% Cu, ABS+10wt% Cu, and ABS+15wt% Cu were the four materials that were tested.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!