Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9935014 | PMC |
http://dx.doi.org/10.1093/europace/euac266 | DOI Listing |
Front Cardiovasc Med
January 2025
Department of Cardiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, Zhejiang, China.
Background: Catheter ablation (CA) is an effective therapeutic option for patients with symptomatic atrial fibrillation (AF). Previous studies have reported silent cerebral lesions (SCLs) detected by magnetic resonance imaging (MRI) after different CA techniques; however, the results were controversial. Therefore, we performed this network meta-analysis (NMA) to assess the incidence of SCLs after cryoballoon, hotballoon, laserballoon, and radiofrequency ablation (RFA).
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Hôpital Cardiologique du Haut Léveque, CHU de Bordeaux, L'Institut de RYthmologie et modelisation Cardiaque (LIRYC), Université de Bordeaux, Bordeaux, France.
Background: Achieving a durable mitral line block using radiofrequency as a part of an anatomical approach for ablation in patients with persistent atrial fibrillation or for treating peri-mitral flutter has always been challenging due to the complex anatomy of the mitral isthmus. Epicardial ablation via the coronary sinus and the vein of Marshall has been proposed to help create durable lesions. Recently, a novel lattice-tip catheter using pulsed field ablation has shown promising results for creating mitral lines, despite limited data.
View Article and Find Full Text PDFWorld J Cardiol
January 2025
Department of Internal Medicine-II, Paracelsus Medical University Salzburg, Salzburg 5020, Austria.
The recurrence of atrial fibrillation (AF) in patients after successful radiofrequency catheter ablation (RFCA) appears to be an unresolved clinical issue and needs to be clearly elucidated. There are many factors associated with AF recurrence, such as duration of AF, male sex, concomitant heart failure, hemodynamic parameters, chronic obstructive pulmonary disease, hypertension, obstructive sleep apnea, hyperthyroidism, smoking and obesity. However, the inflammatory changes are strongly associated with electrical and structural cardiac remodeling, cardiac damage, myocardial fibrotic changes, microvascular dysfunction and altered reparative response.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!