Background: Excimer laser is used to treat coronary artery disease, especially in case of lesions with thrombus and in-stent restenosis (ISR). However, there are no in vivo preclinical studies that have evaluated the pathological reactions of the vessel wall after excimer laser ablation.

Methods: Bare-metal stents were placed in the external iliac arteries of six healthy rabbits. Twenty-eight days later, excimer laser ablation was performed with low-power (45 (fluency)/25 (rate)) in one side, and high-power (60/40) in the opposite side, followed by optical coherence tomography (OCT) evaluation. Rabbits were sacrificed 15 min after the procedure, and histological assessment was performed.

Results: Morphometry analysis of OCT showed similar stent and lumen size between low-power and high-power group. Histological evaluation suggested endothelial cell loss, fibrin deposition, and tissue loss. The low-power group showed significantly less pathological changes compared with the high-power group: angle of endothelial cell loss, 32.4° vs. 191.7° (interquartile range, 8.8°-131.7° vs. 125.7°-279.5°; p < 0.01); fibrin deposition, 1.1° vs. 59.6° (0.0°-70.4° vs. 31.4°-178.4°; p = 0.03); and tissue loss 0.0° vs. 18.2° (0.0°-8.7° vs. 0.0°-42.7°; p = 0.03).

Conclusions: The pathological changes in neointima were more prominent after high-power excimer laser ablation than after low-power excimer laser. To improve safety in clinical practice, understanding the pathological changes of tissues after excimer laser in lesions with ISR is essential.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12928-022-00905-8DOI Listing

Publication Analysis

Top Keywords

excimer laser
16
histological evaluation
8
iliac arteries
8
high-power group
8
endothelial cell
8
cell loss
8
evaluation vascular
4
vascular changes
4
excimer
4
changes excimer
4

Similar Publications

Removal of an entrapped guidewire by excimer laser coronary angioplasty in patients with chronic total occlusion intervention.

BMC Cardiovasc Disord

January 2025

Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.

Guidewire entrapment (GE) is a rare complication that warrants complex interventions or surgical procedures. Here, we report the removal of an entrapped guidewire using excimer laser coronary angioplasty (ELCA) in a case of chronic total occlusion (CTO). Plaque tissue trapped with the guidewire was also removed.

View Article and Find Full Text PDF

Background: Previous studies have proven that 308-nm light-emitting diode(308-nm LED)and 308-nm excimer lamp(308-nm MEL) are effective in treating vitiligo, but there is a lack of comparison of their efficacy for facial lesions.

Objective: To evaluate and contrast the treatment success rates of 308-nm LED versus 308-nm excimer lamp in managing facial lesions among patients suffering from stable non-segmental vitiligo.

Methods: The enrolled 119 patients with 145 lesions were randomly assigned to receive 308-nm LED or 308-nm MEL for two months.

View Article and Find Full Text PDF

Purpose: To evaluate the clinical outcome of laser-assisted surgical correction of high hyperopic or mixed astigmatism using small incision intrastromal lenticule rotation (SMILERO) alone or combined with photorefractive keratectomy (PRK).

Methods: This retrospective case series enrolled 25 eyes with high astigmatism that underwent SMILERO surgery. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), manifest refraction, central corneal thickness, and corneal higher order aberrations were analyzed before surgery and after 3, 6, and 12 months of follow-up.

View Article and Find Full Text PDF

Purpose: To evaluate a new regression-derived nomogram for high myopic astigmatism in small incision lenticule extraction (SMILE) surgery.

Methods: In this prospective study, data from 180 eyes with myopic astigmatism ranging from -2.50 to -4.

View Article and Find Full Text PDF

Purpose: To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).

Methods: This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!