Objectives: The aim of the study is to evaluate the functionality, durability, and temporal biocompatibility of a novel, balloon-expandable polymeric transcatheter heart valve (ATHV) system (InFlow, CardValve Consortium, Poland). Along with expanding TAVI indications, the demand for new transcatheter valves is increasing.
Methods: A surgical ascending aortic banding model was created in 20 sheep. Two weeks later, 16 sheep were implanted with ATHV systems (15-16F). Three animals were euthanized after a 30-day follow-up, four animals after a 90-day follow-up, and six animals after a 180-day follow-up. A follow-up transthoracic echocardiography (TTE) was performed.
Results: There was one procedure-related (6,25%) and two model-related deaths (12,5%; banding site calcification with subsequent infection originating externally from banding). TTE revealed the flow gradients (max/average) of 30,75/17,91; 32,57/19,21; and 21,34/10,63 mmHg at 30, 90, and 180 days, respectively. There were two cases of low-degree regurgitation after 180 days with no perivalvular leak observed. Histopathological analysis showed no valve degeneration at terminal follow-up with optimal healing. Small thrombi were present at the aortic wall adjacent to the base of the leaflets, and between the aortic wall and the stent in most of the valves; however, leaflets remained free from thrombi in all cases. Scanty calcifications of leaflets were reported in three animals evaluated 180 days after implantation.
Conclusion: This preclinical study in the aortic banding model showed good hemodynamic performance, durability, and biocompatibility of the novel ATHV. Furthermore, regulatory studies with longer follow-ups are warranted.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9810075 | PMC |
http://dx.doi.org/10.3389/fcvm.2022.977006 | DOI Listing |
Asian Cardiovasc Thorac Ann
January 2025
Department of Cardiovascular Surgery, Chiba University Hospital, Chiba, Japan.
Background: Endovascular abdominal aneurysm repair (EVAR) offers a less invasive approach to treating abdominal aortic aneurysms (AAA) compared to open repair. However, EVAR is associated with higher rates of reintervention. This study investigates the early and mid-term outcomes of patients who underwent late open conversion including aneurysmorrhaphy after EVAR at our institution.
View Article and Find Full Text PDFTurk Gogus Kalp Damar Cerrahisi Derg
October 2024
Department of Pediatric Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, İstanbul, Türkiye.
Background: This study aimed to present our experience with transcatheter pulmonary debanding, focusing on patient outcomes.
Methods: The retrospective study was conducted with 32 patients (17 males, 15 females; mean age: 3.6±2 years; range, 0.
Turk Gogus Kalp Damar Cerrahisi Derg
October 2024
Department of Pediatric Cardiology, University of Health Sciences, İstanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, İstanbul, Türkiye.
Eur Respir J
November 2024
Institute for Physiology, Charité - Universitätsmedizin Berlin, corporate member of the Free University Berlin and the Humboldt University Berlin, Berlin, Germany.
Zhonghua Yi Xue Yi Chuan Xue Za Zhi
November 2024
Central Laboratory for Birth Defects Prevention and Control, Women and Children's Hospital of Ningbo University, Ningbo, Zhejiang 315012, China.
Objective: To explore the genetic basis for a fetus with increased risk for Down syndrome and cardiac anomalies discovered by prenatal ultrasonography.
Methods: A pregnant woman presented at the Women and Children's Hospital of Ningbo University on August 21, 2023 were selected as the study subject. Clinical data were retrospectively analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!