Background: Fracture of mandibular angle comprises up to one third of mandibular fractures. Many local anatomical factors may increase the risk of such fractures. This study was conducted to investigate the risk of angle fractures with gonial angle measurements.
Material And Methods: A retrospective cross-sectional study was conducted on digital panoramic radiographs of 120 patients with isolated mandibular fractures. The patients were categorized into mandibular angle and other nonangle fracture groups. The gonial angle, antegoneal angle, ramus height was measured using Image J software.
Results: Out of 120 isolated mandibular fractures, 40 (33.33%) are angle fractures and 80 (66 .67%) are other nonangle isolated fractures. Seventy- five percent of angle fractures and 85% of non-angle fractures occurred in males. The average age of angle fracture patients was 28.34±5.2 years and 27.37 ±4.9 years for the non-angle fractures with no significant difference (=0.31). The gonial angle of the angle fractures was 127.60 º ±4.93 º which is 6 degrees greater than the non-angle fractures. The antegonial angle of the angle fractures was 160.67±5.38º which is 5.2 º less than the non-angle fractures. The ramus height in the angle fractures was 18.97±3.7 mm which is 2.5 mm shorter than the nonangle fractures. The difference in these three measurements was highly significant (<0.0001). About 45% of angle fractures and 19% of non-angle fractures occurred in the high gonial angle.
Conclusions: The presence of high mandibular angle doubles the risk of mandibular angle fracture. Angle fracture, gonial angle, Image J, mandiblular fractures, orthopantomograph.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9799995 | PMC |
http://dx.doi.org/10.4317/jced.60003 | DOI Listing |
Langmuir
January 2025
Applied Systems Analysis & Research, Sandia National Laboratories, Albuquerque, New Mexico 87123, United States.
Salt formations have been explored for the permanent isolation of spent nuclear fuel based on their high thermal conductivity, self-healing nature, and low hydraulic permeability to brine flow. Vacancy defect concentrations in salt complicate fracture mechanics not driven by dislocation dynamics and can influence the resulting surface structure. Classical molecular dynamic simulations were used to simulate tensile testing of salt crystals (halite) with vacancy defect concentrations of up to 0.
View Article and Find Full Text PDFMed Biol Eng Comput
January 2025
Department of Pediatric Orthopedics, Xinhua Hospital Affiliated With Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Proximal femoral fractures in children are challenging in clinical treatment due to their unique anatomical and biomechanical characteristics. The distribution and characteristics of fracture lines directly affect the selection of treatment options and prognosis. Pediatric proximal femur fractures exhibit distinctive features, with the distribution and characteristics of the fracture line playing a crucial role in deciding optimal treatment.
View Article and Find Full Text PDFNanotechnology
January 2025
Anhui Agricultural University, Hefei, 230036, P. R. China, Hefei, 230036, CHINA.
Strain sensing fabrics are able to sense the deformation of the outside world, bringing more accurate and real-time monitoring and feedback to users. However, due to the lack of clear sensing mechanism for high sensitivity and high linearity carbon matrix composites, the preparation of high performance strain sensing fabric weaving is still a major challenge. Here, an elastic polyurethane(PU)-based conductive fabric(GCPU) with high sensitivity, high linearity and good hydrophobicity is prepared by a novel synergistic conductive network strategy.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Cerrahpasa Faculty of Medicine, Department of Orthopaedics and Traumatology, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Background: The standard approach for addressing intra-articular calcaneal fractures involves open reduction with plate and screw fixation, with ongoing discourse regarding the application of grafts to address bone gaps. The aim of this study is the temporal comparison of the radiological and functional outcomes in patients undergoing surgery for intra-articular calcaneal fractures, with a specific focus on the use of bone grafts.
Methods: Thirty patients, comprising 13 with iliac grafts and 17 without, were enrolled in the study.
Odontology
January 2025
Department of General Surgery and Medical-Surgical Specialties, University of Catania, 95123, Catania, Italy.
The aim of this study was to assess the cyclic fatigue resistance of a single-file system (i.e., Hyflex EDM OneFile), during continuous rotation and reflex dynamic motion with and without irrigation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!