Ionizing radiation acoustic imaging (iRAI) allows online monitoring of radiation's interactions with tissues during radiation therapy, providing real-time, adaptive feedback for cancer treatments. We describe an iRAI volumetric imaging system that enables mapping of the three-dimensional (3D) radiation dose distribution in a complex clinical radiotherapy treatment. The method relies on a two-dimensional matrix array transducer and a matching multi-channel preamplifier board. The feasibility of imaging temporal 3D dose accumulation was first validated in a tissue-mimicking phantom. Next, semiquantitative iRAI relative dose measurements were verified in vivo in a rabbit model. Finally, real-time visualization of the 3D radiation dose delivered to a patient with liver metastases was accomplished with a clinical linear accelerator. These studies demonstrate the potential of iRAI to monitor and quantify the 3D radiation dose deposition during treatment, potentially improving radiotherapy treatment efficacy using real-time adaptive treatment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10314963 | PMC |
http://dx.doi.org/10.1038/s41587-022-01593-8 | DOI Listing |
BMC Pharmacol Toxicol
January 2025
Biochemistry Department, Faculty of Science, Ain-Shams University, Cairo, Egypt.
Hepatic encephalopathy (HE) is a syndrome that arises from acute or chronic liver failure. This study was devised to assess the impact of a combination of boswellic acid (BA) and low doses of gamma radiation (LDR) on thioacetamide (TAA)-induced HE in an animal model. The effect of daily BA treatment (175 mg/kg body weight, for four weeks) and/or fractionated low-dose γ-radiation (LDR; 0.
View Article and Find Full Text PDFJ Transl Med
January 2025
Department of Medical Oncology, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Anhui Provincial Cancer Hospital, Hefei, 230031, Anhui, China.
Background: Agonistic monoclonal antibodies targeting 4-1BB/CD137 have shown preclinical promise, but their clinical development has been limited by severe liver toxicity or limited efficacy. Therefore, a safe and efficient immunostimulatory molecule is urgently needed for cancer immunotherapy.
Methods: A novel anti-MSLN×4-1BB bispecific antibody (bsAb) was generated via antibody engineering, and its affinity and activity were detected via enzyme-linked immunosorbent assay (ELISA), flow cytometry, and T-cell activation and luciferase reporter assays.
Radiol Phys Technol
January 2025
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan.
Lung function assessment is essential for determining the optimal treatment strategy for radiation therapy in patients with lung tumors. This study aimed to develop radiomics and dosiomics approaches to estimate pulmonary function test (PFT) results in post-stereotactic body radiation therapy (SBRT). Sixty-four patients with lung tumors who underwent SBRT were included.
View Article and Find Full Text PDFRadiat Res
January 2025
Department of Molecular Biosciences, Stockholm University, Stockholm, Sweden.
The role of genetics in susceptibility to radiotherapy-induced toxicities is unclear. A strong impact of genetics should cause correlated toxicities in patients with metachronous double radiotherapy. We ascertained information about demographics, lifestyle, radiotherapy and early toxicities in irradiated tissues for a retrospective cohort of 98 patients from 2 hospitals who underwent two metachronous radiotherapeutic treatments (2007-2022) of different anatomical regions.
View Article and Find Full Text PDFThorac Cardiovasc Surg
January 2025
Pediatric Cardiology, University Hospital Tuebingen, Tubingen, Germany.
Background: Since patients with congenital heart defects (CHD) frequently require life-long medical care and repeat invasive treatment, radiation exposure during interventional procedures is a relevant issue concerning potential radiation related risks. Therefore, an analysis on radiation data from the German Registry for Cardiac Operations and Interventions in patients with CHD was performed.
Methods: From January 2012 until December 2020 a total of 28,374 cardiac catheter interventions were recorded.