Introduction: In this study, sternal complication rates of sternal closures with steel wire or steel wire combined with titanium plate in patients with obesity that underwent cardiac surgery were investigated.
Methods: The data of 316 patients that underwent cardiac surgery between May 2018 and October 2021 were analyzed retrospectively; 124 patients withbody mass index (BMI) ≥ 30 kg/m2 were divided into group I, patients whose sternotomy was performed with steel wires, and group II, patients whose sternotomy was performed with steel wire combined with titanium plates.
Results: A total of 124 patients with BMI ≥ 30 kg/m2 were divided into group I (n=88 [70.9%]) and group II (n=36 [29.1%]). The rate of male patients was found to be significantly higher in group I, whereas the rate of female patients was significantly higher in group II (P<0.001). BMI values were found to be low in group I and high in group II (P<0.001). The distribution of complications was different in the BMI ≥ 35.00-39.99 kg/m2 and ≥ 40 kg/m2 groups (P=0.003). Development of complications was found to be higher in patients with BMI ≥ 40 kg/m2. Sternal dehiscence was observed in two patients in group I, while no dehiscence was observed in group II.
Conclusion: The lower incidence of complications and the absence of non-infectious sternal complications and sternal dehiscence in patients with BMI ≥ 35 kg/m2 that underwent steel wire combined titanium plate sternal closure strengthened the idea that plate-supported sternal closure can prevent sternal complications in high-risk patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10159066 | PMC |
http://dx.doi.org/10.21470/1678-9741-2022-0089 | DOI Listing |
Clin Biomech (Bristol)
January 2025
Department of Kinesiology and Physical Education, Wilfrid Laurier University, Waterloo, Ontario, Canada; Department of Health Sciences, Wilfrid Laurier University, Waterloo, Ontario, Canada. Electronic address:
Background: Fusion changes the biomechanics of the spine leading to the potential development of adjacent segment disease. Despite many studies on adjacent segment disease, it is largely unknown how spinal fixation affects the mechanical properties of the adjacent disc. The purpose of this study was to assess whether axial compression causes mechanical disruption to the annulus when the caudal spinal level is immobilized or injured.
View Article and Find Full Text PDFJ Sep Sci
January 2025
Herbal and Traditional Medicines Research Center, Kerman University of Medical Sciences, Kerman, Iran.
Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic compounds resulting from incomplete burning of organic materials. This work describes the successful layer-by-layer fabrication of a novel zinc oxide nanocomposite made of zinc oxide nanoparticles, aniline, sodium dodecyl sulfate, and modified multi-walled carbon nanotubes on a stainless steel wire by electrodeposition. The coating and extraction conditions were screened, optimized, and validated using factorial design and central composite design, respectively.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Joint R&D Center for Metallic Materials, Metallic Wire and Metallic Card Clothing, Xi'an 710021, China.
The mechanical properties of music wire are contingent upon its microstructure, which in turn influences its applications in music. Chinese stringed instruments necessitate exacting standards for comprehensive performance indexes, particularly with regard to the strength, resilience, and rigidity of the musical steel wires, which differ from the Western approach to musical wire. In this study, SWP-B music wire was selected for investigation through metal heat treatment, which was employed to regulate its microstructure characteristics.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Graduate School of Advanced Science and Engineering, Hiroshima University, Hiroshima 739-8527, Japan.
Application of high-heat input welding on high-tensile strength steels causes deterioration of mechanical properties of the welded joint, due to softening and grain coarsening in the heat-affected zone (HAZ). In this study, low-heat input narrow-gap hot-wire laser welding was applied to 12 mm thick 780 MPa-class high-tensile strength steel plate. Conditions were optimized based on microstructural observations of joints produced at various welding speeds.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
School of Civil Engineering, Central South University, Changsha 410075, China.
To reveal the mechanical behavior and deformation patterns of geotechnical reinforcement materials under tensile loading, a series of tensile tests were conducted on plastic geogrid rib, fiberglass geogrid rib, gabion steel wire, plastic geogrid mesh, fiberglass geogrid mesh, and gabion mesh. The full tensile force-strain relationships of the reinforcement materials were obtained. The failure modes of different geotechnical reinforcement materials were discussed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!