A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of Pharmacokinetics and Tissue Distribution of Four Compounds from in Rat Plasma and Tissues through HPLC-MS/MS. | LitMetric

A rapid, sensitive, selective, and accurate HPLC-MS/MS method was developed and validated for the simultaneous determination of chlorogenic acid, naucleactonin C, khaephuoside A 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside in rat plasma and tissues after oral administration of extracts. Chloramphenicol was used as an internal standard (IS). The plasma and tissue samples were extracted by protein precipitation with methanol-ethyl acetate (1 : 1, v/v) including 0.1% (v/v) formic acid. The chromatographic separation was achieved by using an C18 column with gradient elution using mobile phase, which consisted of 0.1% formic acid water (A) and acetonitrile (B) and the flow rate of 0.8 mL/min. Mass spectrometric detection was performed in multiple reaction monitoring (MRM) mode utilizing electrospray ionization (ESI) in negative mode. The developed method exhibited good linearity (determination coefficients,  ≥ 0.9849), and the lower limits of quantification were 2, 5, 5, and 25 ng/mL for chlorogenic acid, naucleactonin C, khaephuoside A, and 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside. The intraday and interday precisions (relative standard deviation, RSD) were less than 12.65%, while the accuracy was ranged from 86.31 to 114.17%. The recovery rate were 51.85-97.06%, 75.99-106.68%, 77.46-105.35%, and 68.36-103.75% for chlorogenic acid, naucleactonin C, khaephuoside A, and 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside the matrix effects were 50.17-116.62%, 86.75-115.99%, 45.79-87.44%, and 51.60-92.34% for chlorogenic acid, naucleactonin C, khaephuoside A, and 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside in different matrix. The developed method was successfully applied to a pharmacokinetic study and tissue distribution of four compounds in rats after oral administration of extracts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9797307PMC
http://dx.doi.org/10.1155/2022/5297603DOI Listing

Publication Analysis

Top Keywords

chlorogenic acid
16
acid naucleactonin
16
naucleactonin khaephuoside
16
khaephuoside 34-dimethoxyphenyl-1-o--apiofuroseyl1 ⟶ 2--d-glucopyranoside
16
tissue distribution
8
distribution compounds
8
rat plasma
8
plasma tissues
8
oral administration
8
administration extracts
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!