Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A rapid, sensitive, selective, and accurate HPLC-MS/MS method was developed and validated for the simultaneous determination of chlorogenic acid, naucleactonin C, khaephuoside A 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside in rat plasma and tissues after oral administration of extracts. Chloramphenicol was used as an internal standard (IS). The plasma and tissue samples were extracted by protein precipitation with methanol-ethyl acetate (1 : 1, v/v) including 0.1% (v/v) formic acid. The chromatographic separation was achieved by using an C18 column with gradient elution using mobile phase, which consisted of 0.1% formic acid water (A) and acetonitrile (B) and the flow rate of 0.8 mL/min. Mass spectrometric detection was performed in multiple reaction monitoring (MRM) mode utilizing electrospray ionization (ESI) in negative mode. The developed method exhibited good linearity (determination coefficients, ≥ 0.9849), and the lower limits of quantification were 2, 5, 5, and 25 ng/mL for chlorogenic acid, naucleactonin C, khaephuoside A, and 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside. The intraday and interday precisions (relative standard deviation, RSD) were less than 12.65%, while the accuracy was ranged from 86.31 to 114.17%. The recovery rate were 51.85-97.06%, 75.99-106.68%, 77.46-105.35%, and 68.36-103.75% for chlorogenic acid, naucleactonin C, khaephuoside A, and 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside the matrix effects were 50.17-116.62%, 86.75-115.99%, 45.79-87.44%, and 51.60-92.34% for chlorogenic acid, naucleactonin C, khaephuoside A, and 3,4-dimethoxyphenyl-1-O--apiofuroseyl(1 ⟶ 2)--D-glucopyranoside in different matrix. The developed method was successfully applied to a pharmacokinetic study and tissue distribution of four compounds in rats after oral administration of extracts.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9797307 | PMC |
http://dx.doi.org/10.1155/2022/5297603 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!