Dynamic elastography, whether based on magnetic resonance, ultrasound, or optical modalities, attempts to reconstruct quantitative maps of the viscoelastic properties of biological tissue, properties altered by disease and injury, by noninvasively measuring mechanical wave motion in the tissue. Most reconstruction strategies that have been developed neglect boundary conditions, including quasi-static tensile or compressive loading resulting in a nonzero prestress. Significant prestress is inherent to the functional role of some biological tissues currently being studied using elastography, such as skeletal and cardiac muscle, arterial walls, and the cornea. In the present article a configuration, inspired by muscle elastography but generalizable to other applications, is analytically and experimentally studied. A hyperelastic polymer phantom cylinder is statically elongated in the axial direction while its response to transverse-polarized vibratory excitation is measured. We examine the interplay between uniaxial prestress and waveguide effects in this muscle-like tissue phantom using computational finite element simulations and magnetic resonance elastography measurements. Finite deformations caused by prestress coupled with waveguide effects lead to results that are predicted by a coordinate transformation approach that has been previously used to simplify reconstruction of anisotropic properties using elastography. Here, the approach estimates material viscoelastic properties that are independent of the nonhomogeneous prestress conditions without requiring advanced knowledge of those stress conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9793439PMC
http://dx.doi.org/10.1115/1.4056411DOI Listing

Publication Analysis

Top Keywords

waveguide effects
12
prestress waveguide
8
dynamic elastography
8
magnetic resonance
8
viscoelastic properties
8
prestress
6
elastography
6
decoupling uniaxial
4
uniaxial tensile
4
tensile prestress
4

Similar Publications

Improved S-bend optical waveguide loss formula verified by experiments.

Sci Rep

January 2025

Department of Electrical Engineering, Faculty of Science and Technology, University Al Azhar Indonesia, Jakarta, Indonesia.

Curvature of a dielectric waveguide always leads to attenuation of the mode power as it propagates through the curved region. In single mode guides, bending loss becomes significant as the radius of curvature reduces and is strongly dependent on the confinement of the guided mode, so that weakly guiding waveguides can tolerate only large radii of curvature. In this paper we verify our new theoretical version on power loss prediction of S-bend optical waveguides by using analytical theory based on integration of absorption coefficient and compare it to the experimental measurement of such waveguide bends.

View Article and Find Full Text PDF

In the case of waveguide-based devices, once they are fabricated, their optical properties are already determined and cannot be dynamically controlled, which limits their applications in practice. In this paper, an isosceles triangular-coupling structure which consists of an isosceles triangle coupled with a two-bus waveguide is proposed and researched numerically and theoretically. The coupled mode theory (CMT) is introduced to verify the correctness of the simulation results, which are based on the finite difference time domain (FDTD).

View Article and Find Full Text PDF

This paper presents a high-performance circularly polarized (CP) magneto-electric (ME) dipole antenna optimized for wideband millimeter-wave (mm-wave) frequencies, specifically targeting advancements in 5G and 6G technologies. The CP antenna is excited through a transverse slot in a printed ridge gap waveguide (PRGW), which operates in a quasi-transverse electromagnetic (Q-TEM) mode. Fabricated on Rogers RT 3003 substrate, selected for its low-loss and cost-effective properties at high frequencies, the design significantly enhances both impedance and axial ratio (AR) bandwidths.

View Article and Find Full Text PDF

Suspended Slot Membrane Waveguide Based on Germanium-on-Silicon-on-Insulator at λ = 4.23 µm for CO Monitoring.

Micromachines (Basel)

November 2024

Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland.

In this work, we propose a novel suspended slot membrane waveguide (SSMW) utilizing a germanium-on-silicon-on-insulator (Ge-on-SOI) platform for carbon dioxide (CO) gas-sensing applications. The design and analysis focus on the absorption line of CO in the mid-infrared region, specifically at a wavelength of 4.23 µm.

View Article and Find Full Text PDF

Waveguide evanescent field fluorescence microscopy (WEFF) is an evanescent-based microscopy that utilizes a confined thin film of light, around 100 nm, to image the plasma membrane of cells attached to a waveguide. Low photobleaching and low background besides its high axial resolution allows time-lapse imaging to investigate changes in cell morphology in the presence or absence of chemical agents. Both large field of view (FOV) and uniform illumination are very important while imaging cell-substrate contacts with an evanescent field.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!