Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Electrolyte disturbance is very common and harmful, increasing the mortality of critical patients. Hence, rapid and accurate detection of electrolyte levels is vital in clinical practice. Laser-induced breakdown spectroscopy (LIBS) has the advantage of rapid and simultaneous detection of multiple elements, which meets the needs of clinical electrolyte detection. However, the cracking caused by serum drying and the effect of the coffee-ring led to the unstable spectral signal of LIBS and inaccurate detection results. Herein, we propose the ordered microarray silicon substrates (OMSS) obtained by laser microprocessing, to solve the disturbance caused by cracking and the coffee-ring effect in LIBS detection. Moreover, the area of OMSS is optimized to obtain the optimal LIBS detection effect; only a 10 uL serum sample is required. Compared with the silicon wafer substrates, the relative standard deviation (RSD) of the serum LIBS spectral reduces from above 80.00% to below 15.00% by the optimized OMSS, improving the spectral stability. Furthermore, the OMSS is combined with LIBS to form a sensing platform for electrolyte disturbance detection. A set of electrolyte disturbance simulation samples (80% of the ingredients are human serum) was prepared for this platform evaluation. Finally, the platform can achieve an accurate quantitative detection of Na and K elements (Na: RSD < 6.00%, R = 0.991; K: RSD < 4.00%, R = 0.981), and the detection time is within 5 min. The LIBS sensing platform has a good prospect in clinical electrolyte detection and other blood-related clinical diagnoses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9774860 | PMC |
http://dx.doi.org/10.1364/BOE.477565 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!