Scheimpflug-based corneal densitometry is a clinically verified method for assessing corneal transparency. Nevertheless, the estimates of corneal densitometry appear to be correlated with age and eye biometry parameters, such as the anterior chamber depth or the pupil size, and that ensues a convoluted conditional estimation problem, where it is difficult to interpret the results. This study aims at devising a methodology for compensating for such confounding factors by using, as a research platform, a commercially available Scheimpflug camera that allows exporting images in a dynamic fashion, allowing averaging the results from multiple acquisitions. Two approaches are considered, one based on appropriately normalizing the line densitometry signal and one based on image histogram equalization. Then, three parameters for describing corneal densitometry are derived including the mean value of backscatter and the scale and shape parameters of the Weibull distribution estimated in regions of interest encompassing parts of corneal stroma. The results show that, unlike the non-normalized measures, the proposed approaches lead to parameters that are not correlated with age nor the eye biometry.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9774844 | PMC |
http://dx.doi.org/10.1364/BOE.473534 | DOI Listing |
Cornea
December 2024
Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, Canada.
Purpose: To present the clinical, topographic, and densitometry outcomes of patients with corneal fibrosis treated with topical losartan.
Methods: In this case series, patients with corneal scars treated with topical losartan 0.8 mg/mL 4 times a day for 6 months were included.
Cureus
October 2024
Ophthalmology, Hoopes Vision, Draper, USA.
Purpose: The aim is to assess for any lasting changes in corneal densitometry (CD) in patients who underwent small incision lenticule extraction (SMILE) and developed early transient postoperative corneal haze.
Methods: This retrospective chart review analyzed 98 eyes from 49 patients who underwent SMILE at the Hoopes Vision Clinic and had one-year postoperative Pentacam CD (Oculus Optikgeräte GmbH, Wetzlar, Germany). These were compared to 78 eyes from 42 unoperated myopic control patients with documented CD measurements.
Clin Ophthalmol
October 2024
Anterior Segment Department, Miranza Begitek, Donostia-San Sebastián, Spain.
Purpose: To compare corneal aberrometry, densitometry, and refractive outcomes of single-step Transepithelial Photorefractive Keratectomy (Trans-PRK) with and without epithelial thickness customization.
Patients And Methods: This was a prospective, interventional, randomized controlled study. Patients undergoing Trans-PRK using the WaveLight EX500 laser with StreamLight software (Alcon Laboratories, Forth Worth, TX, USA) were randomly assigned to control (55 µm standard epithelial thickness) or customized (thinnest point of epithelial thickness for each patient) groups.
Ophthalmologie
October 2024
Department of Ophthalmology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Köln, Deutschland.
Surv Ophthalmol
November 2024
Department of Ophthalmology, the Second Hospital of Jilin University, Changchun, Jilin 130041, China. Electronic address:
Corneal densitometry (CD) uses the biological properties of the cornea to visualize the morphology of the cornea and determine the degree of corneal transparency. At present, it is an emerging metric that has shown promise in various clinical diagnosis and evaluation of eye diseases and surgeries. We introduce the different methodologies used to measure CD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!