Introduction: The purpose of this study is the evaluation of radial collapse, based on the number of screws used in the metaphyseal region and by distal dorsal distance (DDD) and lunate facet distance (LFD) measurement.

Materials And Methods: Between 2015 and 2019, 60 patients who were being treated with volar locking plates due to isolated distal radius fracture were evaluated. Control radiographs were taken on the first day and at 3rd-, 6th- and 12th-month follow-ups. Distal dorsal cortex distance and lunate facet distance were measured in the lateral radiographs. The number of screws used in the metaphyseal region was also evaluated. According to the number of screws, the amount of collapse was analysed based on both the LFD and the DDD.

Results: The mean age of patients was 43.5±12.7 years. Thirty-three of the patients included in the study were male and 27 were female, and the minimum follow-up period was one year. According to the mean number of screws, groups were defined as up to 6 screws or 7 screws and above. There was a statistically significant difference between the groups in terms of DDD collapse at the 6th-month and 12th-month follow-ups (p<0.005). It was observed that the radial collapse and decrease in DDD and LFD were lower in plates with seven screws and above.

Conclusion: Decreases in either DDD or LFD, or radial collapse were observed less in patients who had seven or more metaphyseal screws inserted. These findings might be useful for surgeons treating distal radius fractures to reduce radial collapse.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9791896PMC
http://dx.doi.org/10.5704/MOJ.2211.006DOI Listing

Publication Analysis

Top Keywords

number screws
16
radial collapse
8
distal radius
8
screws metaphyseal
8
metaphyseal region
8
distal dorsal
8
lunate facet
8
facet distance
8
12th-month follow-ups
8
screws
7

Similar Publications

Experimental dataset of a model-scale ship in calm water and waves.

Data Brief

February 2025

Maritime Engineering Research Group, School of Engineering, University of Southampton, SO16 7QF UK.

This article presents data derived from a series of experiments conducted on a scaled model ship, examining its performance in both calm water and regular waves. The acquisition of high-quality experimental data is essential for refining Computational Fluid Dynamics (CFD) simulations and modifying analytical methods to evaluate the powering performance of ships. Despite notable advancements in numerical models, there exists a corresponding imperative to elevate the precision of measurements and insights obtained from towing tank tests.

View Article and Find Full Text PDF

Background: In atlantoaxial instabilities, posterior C1/C2 fusion using lateral mass screws (LMS) or pedicle screws (PS) in a mono- or bicortical position in the atlas is a typical treatment. The bone microstructure and positioning of the screw trajectories appear to be of significant relevance for stability.

Purpose: The aim of this study was a comparative analysis of the mechanical durability of screw fixation concerning microstructural characteristics of the trajectories of LMS and PS in mono- and bicortical position.

View Article and Find Full Text PDF

CT imaging findings in symptomatic patients with and without revision surgery after reverse shoulder arthroplasty.

Skeletal Radiol

January 2025

Department of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.

Objectives: To evaluate CT imaging findings in symptomatic patients with and without revision surgery (RS) after reverse shoulder arthroplasty (RSA).

Materials And Methods: In this retrospective study, two radiologists assessed CT imaging findings in symptomatic patients with RSA over 5 years, including material fracture and loosening of the peg, baseplate, screws, and humeral stem, screw positioning, prosthesis dislocation, glenoid notching, fractures, and deltoid muscle quality. The primary outcome parameter was RS.

View Article and Find Full Text PDF

Background: This study aims to demonstrate the 3-dimensional pattern of the nutrient vessels of the triquetrum using micro-computed tomography and determine the safe region for screw applications to the bone.

Methods: Seven fresh frozen cadavers' ulnar and radial arteries were injected with Microfil MV-117. Triquetral bones were dissected and examined using micro-computed tomography.

View Article and Find Full Text PDF

Objective: The pedicle screw insertion technique has evolved significantly, and despite the challenges of precise placement, advancements like AR-based surgical navigation systems now offer enhanced accuracy and safety in spinal surgery by integrating real-time, high-resolution imaging with virtual models to aid surgeons. This study aims to evaluate the differences in accuracy between novel AR-guided pedicle screw insertion and conventional surgery techniques.

Methods: A randomized controlled trial was conducted from March 2019 to December 2023 to compare the efficacy of AR-guided pedicle screw fixation with conventional freehand surgery using CT guidance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!